User manual

Chapter6 Troubleshooting
191
Fault Content of checking Corrective measure
Motor rotate but
can’t shift
Whether the connection of
frequency circuit is correct
Correct the connection
Whether the load is too heavy
Reduce the load or increase
Acc/Dec time
Motor’s rotate
speed is too fast
or too low
Whether the max output
frequency setting is correct
Check the setting of
maximum output frequency
Use a rectifying voltmeter to
test Whether the voltage drop
between the motor’s terminals
is too much
Check V/F characteristics
Motors rotate
speed isn’t
steady
Whether the load is too heavy Reduce the load
Whether the load wave Reduce waving of the load
Is there any phase loss of
power supply
Check phase loss of power
supply.
For single-phase power
supply, connect AC reactor to
power supply
Whether the frequency-giver is
steady or not
Check the frequency-giver
Noise of the
motor is too loud
Bearings’ abrasion,
lubrication, rotor’s
eccentricity
Repair the motor
Whether the carrier-frequency
is too low
Increase the carrier wave
frequency
Vibration of the
motor is too
much
Is there any mechanical
resonance
Adjust the jump frequency
Whether the under-chassis of
the motor is level
Adjust the under-chassis of
the motor
Whether the output of the three
phases is balanceable
Check output of the inverter