User manual
Chapter 8 Maintenance
The daily inspecting contents and cautions are listed in Table 8-1.
Table:8-1 The daily inspecting contents and cautions
serial
numb
er
Inspectio
n
Inspection
part
Inspection item Access standard
part
1 Display
LED
monitors
Display normal or
abnormal
Confirmed by
operation mode
Cooling
system
Fan
Rotate flexibly ,Abnormal
sound
Without abnormal 2
3 Main part
Inside
cabinet
Heat, abnormal sound or
smell
Without abnormal
4
Environ
ment
Ambient
Temperature humidity,
dust,
Hazardous gas
According to 2.2
5 Voltage
Input/outp
ut
terminal
Input/output Voltage
normal of not
According to
appendices 2
6 Load Motor
Heat, abnormal sound of
vibration
No abnormal
8.1.2 Regular Maintenance
The power supply must be cut off before regular maintenance. Only after the monitor has
no display and charge LED has lit off 5-10 minutes can the maintenance begin. On the
other hand, you will risk electric shock because there are storage capacitors within the
inverter that will hold charge even after the input power is disconnected.
The regular maintenance contents and cautions are listed in Table 8-2.
Table: 8-2 The regular maintenance contents and cautions
Component Check Corrective Action
External
Terminals,
Loose screws or
connectors
Connectors,
Mounting Screws,
etc.
Securely tighten.
Heatsink Build-up of dust and dirt
Blow with dry, compressed
air( 39.2×10
4
to
58.8×10
4
Pa(4 to
6kg.cm
2
)pressure)
Printed Circuit
Board
(PCB)
Accumulation of
conductive dust of oil
Blow with dry, compressed
air( 39.2×10
4
to
58.8×10
4
Pa (4 to 6kg.cm
2
)
pressure), if dust and oil cannot be
removed. replace the board
199