Appendix 4 MODBUS Communication
MODBUS registers address:
Function parameter No. (DEC) MODBUS registers address No. (HEX)
(ENTER to save data) (00FFH)
(Only write-in data)
(0001H001FH)
(Only read-out data)
(0020H004FH)
P0.00P0.22 0100H 0116H*
P1.00P1.16 0200H 0210H
P2.00P2.26 0300H 031AH
P3.00P3.26 0400H 041AH
P4.00P4.25 0500H 0519H
P5.00P5.20 0600H 0614H
P6.00P6.11 0700H 070BH
P7.00P7.18 0800H 0812H
P8.00P8.04 0900H 0906H
P9.00P9.09 0A00H 0A09H
PA00 PA.09 0B00H 0B09H
Pb.00Pb.06 0C00H 0C08H
PC.00PC.22 0D00H 0D16H
Pd.00Pd.15 0E00H 0E10H
PE.00PE.12 0F00H 0F0CH
PF.00PF.03 1000H 1004H
(Reserved, for parameter
extending)
(1100HFFFFH)
*Note
In the function table, the MODBUS address coding rules:
high 8 bits HI = (Parameter group number + 1);
low 8 bits LO = (Function Parameter number).
The function parameter P0.11 can be only read. And function group PF can’t be read and
written.
Reading reserved address will return communication error code “02 H”.