User manual

Chapter 3 Operation
0.00
50.00 49.99 49.50
output
frequency
Turn left the
digital
encoder,the
keyboard will
automatically
come into
frequency setting
state.Unit Hz
will blink.And
the monitoring
object is setting
frequency
turn left 1
time,seting
frequency
decrease
0.01Hz
Keep on
turnning,
the decrease
step length can
reach to
0.10Hz,seting
frequence can
decrease 0.10Hz
1 time.
The maximal
step length
can reach
to
1Hz.Depress
the Enter
key to save
the desired
value.
40.00
3 seconds
later,the
keyboard will
automatically
return to the
original
monitoring
object.
0.00
-
-
-
-
Stop
trunning
Display
of LED
Operation
of key
Figure 3-6 Flow chart of frequency setting
Note:
If in the monitoring state, and the monitoring object is PID rotate speed or analog PID
feed. Turn the digital encoder right
+
or left
-
, it can directly change the value
as the change of the frequency setting.
Setting the parameters value: Example: change jog accelerate time from 6.0 second to
3.2 second
0.00
P2.01
monitoring
state
go into
programming
state.display
parameter
group menu
Enter
into
parameter
code
number
menu
turn right 1
time,chose
parameter
code
number
P2.01
Enter into
parameter
value menu
Turn left 3
times to
chang the
number to 3
save the
changed value
and exit to
parameter
code number
menu
Display
of LED
Operation
of key
Shift to
change the
blinking
place to
right
Exit to
parameter
group
menu
Turn right 2
times to
change the
number to 2
Exit from
the
programming
state
turn right 2
times,chose
parameter
group
P2
P2.00
-P2--P0-
-P2-
P2.02
003.
2
003.
0
00
6
.0 00
3
.0
ENTER
PRG
ESC
ENTER
>>
PRG
ESC
PRG
ESC
ENTER
ENTER
+
+
+
-
Figure 3-7 Flow chart of parameter setting
Note:
In the function parameter menu, if the display has no flickering number, it means that the
parameter cannot be modified. The reasons maybe:
Modifying the value is forbidden because the parameter is actual measure value, or
running record value or fixed value. The function parameter cannot be changed when
the inverter is at running state. However, it can be changed at stop state.
So stop the inverter and then change the parameter value.
48