User manual
Chapter 3 Operation
3.5 Operation of Control Circuit Terminal
Assume that the inverter needs to run forward at 30.00 Hz at first, and then stop by
terminal, using the keyboard can take the following steps to realize the task:
Sequence of terminal operation:
Power
on
Frequency
setting
Running
Forward
30.00Hz
Stop
abc
d
Figure 3-13 Sequence of terminal operation
Operation steps:
55
30.00
Close
between
co n tro l circu it
terminals FOR
and COM to
p erfo rm
forward run
open
between
control
circuit
terminals
FOR and
COM to
stop
operation.
0.00
go from
parameter
group
menu to
parameter
code
number
menu
Display
of LED
Operation
of key
P0.00
-P0-
save the
setting
value
and
return to
parameter
code
number
menu
return to
parameter
group menu
-P0-P0.01
return to
monitoring
state
0.00
ENTER
ENTER
ENTER
PRG
ESC
-
50.00
go to
parameter
value
menu
30.00
PRG
ESC
PRG
ESC
Open
X1-COM
Close
X1-COM
change
the
nuber
from
5 to 3
monitoring
state
Figure 3-14 Flow chart of running and stop operation by terminal