User manual
Chapter 4 Parameter Index
P1: Start/Stop Control
Function
code
Function
Name
LCD
Display
Range of settings
Default
Change
MODBUS
Address
P1.00
Starting
mode
Starting
mode
0: Start directly
1: Brake first and
then start at start
frequency
2: Start after speed
tracking (the
mode is only valid
for the motor of
35R5GB/37R5PB
or above)
Note: the startup
includes power on,
power recovery after
an instantaneous off,
external fault reset,
restart after coast to
stop.
0
○ 0200
P1.01
Starting
frequenc
y
Starting
frequency
0.10~60.00Hz
0.50Hz
○ 0201
P1.02
Starting
frequenc
y holding
time
Starting
holding
time
0.0~10.0s
0.0s
○ 0202
P1.03
DC
injection
braking
current at
start
Brake
current at
start
Type G: 0.0~
100.0% of inverter
rated current
Type P: 0.0~80.0%
of inverter rated
current
0.0%
○ 0203
P1.04
DC
injection
braking
time at
start
Brake
time at
start
0.0~30.0s
0.0s
○ 0204
P1.05
Acc/Dec
mode
Acc/Dec
mode
0: Linearity
1: S-curve
2: (Reserved)
3: (Reserved)
0
○ 0205
61










