User manual

Chapter 4 Parameter Index
62
Function
code
Function
Name
LCD
Display
Range of settings
Default
Change
MODBUS
Address
P1.06
Time of
S-curve
initial
Time of
S-curve
initial
10.050.0%
(Acc/Dec Time)
P1.06+P1.0790%
20.0%
0206
P1.07
Time of
S-curve
rising
Time of
S-curve
rising
10.080.0%
(Acc/Dec Time
P1.06+P1.0790%
60.0%
0207
P1.08
Stop
mode
Stop
mode
0: Deceleration to
stop
1: Coast to stop
2: Dec +DC braking
0
× 0208
P1.09
DC
injection
braking
frequenc
y at stop
DC
injection
braking
frequency
at stop
0.00
MIN(50.00Hz,
Frequency upper
limit)
0.00Hz
0209
P1.10
DC
injection
braking
waiting
time at
stop
DC
injection
braking
waiting
time at
stop
0.0010.00s
0.00s
020A
P1.11
DC
braking
current at
stop
DC
injection
braking
current at
stop
This value depends
on the inverter model
Type G: 0.0
100.0% (inverter
rated current)
Type P: 0.080.0%
(inverter rated
current)
0.0%
020B
P1.12
DC
braking
time at
stop
Braking
time at
stop
0.030.0s
0.0s
020C
P1.13
Dynamic
braking
selection
Dynamic
braking
selection
0: Dynamic braking
is disabled
1: Dynamic braking
is enabled
1
× 020D