User manual
Chapter 4 Parameter Index
89
Function
code
Function
Name
LCD
Display
Range of settings
Default
Change
MODBUS
Address
P7.11
Integration
adjust
selection
Integration
adjust
selection
0: Stop
Integration
Adjust when
frequency
arrive at limit;
1:Continue
Integration
Adjust when
frequency
arrive at limit
0
× 080B
P7.12
PID preset
frequency
PID preset
frequency
3004GB or
below:
0.00~650.0Hz
35R5GB/37R5PB
or above:
0.00~400.0Hz
0.00Hz
○ 080C
P7.13
Hold time
of PID
preset
frequency
Hold time
of PID
preset
frequency
0.0~3600s
0.0s
× 080D
P7.14
Analog
closed loop
measuring
range
Analog
closed loop
measuring
range
1.0~999.9
100.0
○ 080E
P7.15
Enable
dormancy
Enable
dormancy
0: Disable
1: Enable
0
× 080F
P7.16
Dormancy
delay
Dormancy
delay
0~999s
120s
○ 0810
P7.17
Dormancy
threshold
Dormancy
threshold
0~Frequency
upper limit
20.00Hz
○ 0811
P7.18
Awa kening
threshold
Awa kening
threshold
0.0~999.9
3.0
○ 0812










