Installation guide

3 Programming of Parameters
3.1 Programming through Phone
3.1.1 Entry to Programming
The New Door Phone NUDV will be set to programming mode in two ways:
1. by password – only incoming call! – answer the telephone and dial a
number, where the guard is lined
(either branch number, if connected to
branch exchange or number of state line to object, where the guard is placed
and let you put through to branch directly connected with guard)
. The guard
will answer (you hear tone for answering – see Chapter 2.1 page 20)
up to 10 sec dial #xxxx, where xxxx is the service number for entry to
programming and if O.K., the registration tone to programming will
sound and afterwards the programming tone is heard (see Chapter 20
page 20). In basic setting is xxxx = 0000.
2. by "SERVICE" jumper – only incoming call! – you will realize the
connection with guard in the same way as in art. 1, but when the
SERVICE jumper is connected, then the guard after answering directly
comes to programming mode – you hear tone for answering,
registration tone to programming and afterwards the programming tone
is heard. (see Chapter 2.1 page 20).
3.1.2 Programming of parameters
The initial state for programming is signaled by programming tone and
the guard will come back to this state always after time expiration (5 seconds)
even you started to program anything.
When programming two types of parameters will occur. Partly they are
parameters with fixed length – the majority of them they are, then the
programming is affirmed and the parameter is always recorded immediately
after mandatory length fulfillment by acknowledge tone and partly the
parameters with variable length (parameter 1,2,32,33,34), followed with
confirmation and the recording of the parameter after inactivity period expires
(5 sec). The only case with immediate recording of parameters is the fulfillment
of max. number of recorded signs (numbers) – by parameters 1 and 2 it is 16,
by parameters 32,33,34 it is 6.
If during programming you enter number (sign) not allowable by its extent
then the guard immediately emits an error tone, the parameter will not be
recorded nor changed, the guard will come to initial state and it is possible to
repeat the parameter setting or program another parameter.
The guard stays inactive in programming mode for 34 seconds, then he
will automatically hang up. By every dialing of DTMF tone this period is set up
repeatedly. The selection of parameter 9 can also end the programming mode.
Note 1.
if you wish to keep the connection (extend the 34 seconds period) than the
customer will think over the other setting, so pressing e.g.. 7, 0, * or # form time to time