2 password for relay closing from buttons or keyboard [2 to 6 digits]. Total 6
passwords, they are controlled by Day/Night; the combination is entered
either by DoorPhone buttons (first 1/2 buttons) or from attached keyboard
(after pressing of key symbol). The relay closing influences the set switch
mode and Day/Night switchover. By setting of choice mode of 2 number
groups the DoorPhone is permanently in DAY mode.
By password choice some rules have to be observed:
§ Select passwords in way not to find its combination out from
wear of certain buttons by frequent use.
§ Select the first password button from frequentless button for
direct dialing (-extends choice time)(-not valid for keyboard).
§ Pay attention to congruity of password numbers when one
password includes other one, e.g. relay 1 has 1234 and relay 2
has 12345. Then after pressing button 4 the only relay 1 is
called, but password choice 234 for relay 2 can call both relays
after pressing switch 4.
3 Command from phone after relay closing [2 digits]. The same command can
be set for both relays, then they are activated at the same time. The
advantage is to set the same command both for relay closing and command
to DoorPhone hanging up (page 22).
4 Duration of relay closing in second [2 digits 01-99]
5 To prohibit the control during incoming call is important e.g. when using
relay 2 in mode 1 for control of garage gate opening, when the electronics
opens the gate and the gate is closed by car passage. Then the control from
phone could undesirably cause the permanent gate opening (not closed
no car passage).
6 time in second between close relays 1 and 2 by mode setting of relay 2 is 5
(gradual opening) [2 digits 01-99]
7 Default value presetings to the firm settings. After making changes use
the save changes button.