HEMLOCK OWNER’S MANUAL INSTALLATION GUIDE WARRANTY
HEMLOCK OWNER’S MANUAL THANK YOU FOR CHOOSING TO BUY AN ALPINE HAND DRYER. WARNING A comprehensive installation guide is enclosed with the unit packaging. This contains detailed information on the correct installation of the unit which MUST be adhered to completely. Damage caused by incorrect installation is not covered by your warrantee. If hardwired, installation MUST be by a qualified electrician. The instructions in this manual and the installation guide must be followed completely.
HEMLOCK CLEANING / MAINTENANCE Before servicing or cleaning the unit, switch power to off at the service panel. Lock to prevent power from being switched on accidentally. If you cannot lock the service panel, securely fasten a prominent warning device, such as a tag, or label, to the panel. WARNING: 1. Do not pressure-wash the unit. 2. Do not clean the filter or allow it to come in contact with water.
HEMLOCK INSTALLING THE HAND DRYER UNIT CAUTION: Make sure that no electrical wiring or pipe work are located directly behind area of drilling. 1. If hardwired, disconnect power source of electricity previously bought to the hand dryer location. 2. Be sure there is no obstruction between floor and dryer. If mounted over counter top place dryer no less than 16 inches above counter. Do not install dryer over wash basin. 3. Mark wall at appropriate mounting height according to height guide below.
HEMLOCK LIMITED WARRANTY BEFORE REQUESTING SERVICE PLEASE REVIEW THE TROUBLESHOOTING GUIDE. TERMS AND CONDITIONS OF THE ALPINE 5 YEAR LIMITED WARRANTY Your warranty begins from the date of purchase. Please retain your proof of purchase. If you do not have your proof of purchase the warrantee begins 30 days after the date of manufacture, according to Alpine records. The warrantee coverage only covers the original owner. If hardwired, proof of installation date by a license electrician is required.
TROUBLESHOOTING Dryer does not turn on Check power to the unit and connections. Verify dryer is receiving the correct voltage at the Terminal Block (check dryer label on the outside bottom of the cover). 2. Adjust the sensor range (refer to wiring diagram sheet). 3. Check for loose, disconnected or improper wiring. Especially make sure that the sensor wires are well connected (refer to wiring diagram sheet).
m bl y He ati ng LE D Li gh t A ss He at in g M ot or P ow er Po we r se m bl y Pr og ra m Bo ar d As Mo tor These two connector is interchangeable M ai n Bo ar d As se y Tu rn clo ck wi se to ng e in cr ea se se ns or ra Se ns or As se m bl em bl y Brown Blue Black Heat Element L 120V 60Hz N G Motor Yellow Grounding HOT/COLD Switch Hand dryer diagram Black Terminal Block
Open cover and take hand dryer from wall Base fix screw Allen key 1. Remove and retain 2 side security hex cover screws by allen key then move the cover. 2. It is recommended to take hand dryer from wall ONLY when replace a new motor or two side cover fix brackets . Loose 4 base fix screw then take hand dryer from wall. Replace cover fix brackets Bolt Spring gasket Bracket Bracket fix screw Gasket Hand dryer base Grounding wire 1.
Replace Main circuit board Main Board 1. Disconnect all the wires form the circuit board. 2. Unscrew the 3 screws and remove the main board. 3. Connect new main board. 4. Reconnect all the wires (see Diagram on page 1). Replace LED Lock LED 1. Remove nozzle by loosening the nozzle screw (be sure not to lose it). 2. Remove LED from LED house and disconnect it from the main board. It is recommended to use a slotted screw driver to push the lock out a little then push the LED down lightly. 3.
Replace filter or HEPA filter (If supplied) HEPA If it is a normal air filter: Just pull it out as it is soft. Then replace a new one. If it is a HEPA air filter: 1. Remove air inlet right cover by loosening 4 screw(Be sure not to lose them). 2. Replace a new HEPA. 3. Replace over and do not over tight it. Replace motor Motor fix rubber ring Motor fix bracket Motor 1. Disconnect motor wire from motor to Main Board. 2. Move air inlet right cover by loosening 4 screw(Be sure not to lose them). 3.
' % ( )) " ( ! ! % ! # $ ! % & # $ ! % & ! ! " & &