3. Eligibility requirements for regulatory approval:
As a part of regulatory certification, ALPS will provide an approval for the United States of America in
the form of module.
For regulatory certification for Canada, ALPS UGEA3A has not been certified.
Therefore, our customer could not sell the entire product providing ALPS UGEA3A in Canada.
The regulatory approval is required for the end-product, where end-user integrates ALPS UGEA3A
into entire product in non-compliance to FCC certification conditions of ALPS UGEA3A.
The conditions for the certification of ALPS UGEA3A and related information are described below.
ALPS wishes that our customer for the end product would contact with us about what conditions of
UGEA3A have been certified by FCC.
3.1 Compliance statement to FCC
This module complies with part 15 of the FCC rules. Operation is subject to the following conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
3.2 RF exposure compliance
This module, UGEA3A will be applied as “mobile device”.
Because the external antenna of the module is intended to be placed on the location like that persons
body (excluding extremities: hands, wrists, feet and legs) be a faraway from the antenna.
For example of the location: a top of the roof of an automobile.
This equipment complies with FCC radiation exposure limits set forth for at uncontrolled exposure as
mobile device.
Therefore, this module should be installed and operated with minimum distance at least 20cm between
the radiator and persons body (excluding extremities: hands, wrists, feet and legs) and must not be
co-located or co-operated with any other antenna or transmitter.
3.3 Requirements to end product
The following provisions for end product will be required on the FCC regulation.
(1) RF exposure compliance
ALPS wishes that our customer will instruct to the end user for RF exposure compliance as stated
below.
This equipment should be installed and operated with minimum distance at least 20cm
between the radiator and persons body (excluding extremities: hands, wrists, feet and legs)
and must not be co-located or operated with any other antenna or transmitter.
(2) External regulator
The regulated voltage of 3.6V dc +0.1/-0.1V shall be supplied to cellular Power Amplifier and pcs
Power Amplifier equipped within the UGEA3A module through the external regulator which our
customer be required to provide into end product.
(3) Antenna
ALPS wishes that our customer shall use the UGEA3A module without any modifications
including antenna.
Please refer to table of major function of prior page for the antenna specifications.
If customer use a unique antenna, the FCC certification is required for the end product.
(4) Markings
To satisfy FCC exterior labeling requirements, the following text must be placed on the exterior of