Altai A3-Ei Dual-band 3x3 802.11ac Wi-Fi Access Point
Installation Guide
is very important that using shielded outdoor rated Ethernet cable
together with shielded RJ45 jack for outdoor deployment at the time.
The differentiation between unshielded twisted pair (UTP) Ethernet
cable and foiled twisted pair (FTP) cable is that the latter has a small
wire under the foil. This wire (preferably 2 cm longer than other wires),
also known as the drain wire, should be wrapped around the outside of
the shield when installing the shielded RJ45 plug. It is very important to
have direct contact between the foil and the shield of the RJ45
connector.
Figure 15 shows a shielded, metal-enclosed RJ45 connector. First the
boot is slid onto the cable, then the cable shield and drain wire are
folded back, next the load bar is loaded with the eight inner cable
conductors, then the load bar/cable assembly is inserted into the
connector housing and crimped. Finally, the boot is slid over the
assembly for additional strain relief.
Figure 15 - Shielded, metal-enclosed RJ45 connector
Here are some more tips to improve the effectiveness of your surge
protection scheme for fighting against lightning and power surges:
Keep cable runs as straight as possible.
Always run outdoor PoE cable inside of the mounting pole if
possible. The mounting pole will as insulation and help passing
surges to ground.
Use PoE cable and RJ45 plug that is shielded and is rated for
outdoor or direct burial;
Test the conductivity of the grounding system to ensure the
installation is solid and electrically capable of grounding any
ambient surge or static.