4.1. Basic Configurations
This section covers the basic configuration on A8n (ac) Series products.
4.1.1. Synchronize AP’s system clock with NTP
server
Figure 15 NTP Setting
1. Go to Configuration > System
2. Change the following settings:
NTP Server IP Type in either the domain name / IP address of NTP
server which you want to synchronize with.
NTP Polling Interval Type in the interval in second between each
synchronization request from the AP to NTP server. The default
setting is 600 seconds
NTP Time Zone Select the appropriate time zone. The default
setting is Asia/Hong Kong
Daylight Saving Time Select the checkbox if your place has
daylight saving time
3. Click Submit
4. Click Save & Apply
Note:
- IP Address Type is changed by AP automatically based on
whether IPv6 is enabled or not
- If providing NTP server’s domain name in NTP Server IP, you
must provide valid DNS server information (see 4.1.2 on page
15 for more detail). Otherwise, NTP setting cannot take effect.