Specifications

28
LOCAL BUZZER ACTIVATION BY:
SWITCH → BUZZER KILL .
LED BLINKING → BUZZER always active.
LED OFF → The BUZZER is turned off when the local BUZZER
KILL is active. Factory default.
HEADSET MICROPHONE TYPE (PHANTOM)
SWITCH → TALK A .
LED BLINKING → Phantom power enabled in the HEADSET connector
(electret microphone).
LED OFF → Phantom power disabled in the HEADSET connector
(dynamic microphone). Factory default.
HEADSET MICROPHONE TYPE (GAIN)
SWITCH → LISTEN A .
LED BLINKING → HEADSET microphone gain at LOW (electret
microphones).
LED OFF → HEADSET microphone gain at HIGH (dynamic
microphones). Factory default.
PANEL MIC KEY MODE: SINGLE OR DUAL MIC
SWITCH → CALL A .
LED BLINKING → Single mode, when the PANEL MIC is active, the
HEADSET mic is disabled.
LED OFF → Dual mode, when the PANEL MIC is active, the
HEADSET mic is still enabled. Factory default.
BUZZER LEVEL
SWITCH → TALK B.
LED BLINKING → BUZZER level high.
LED OFF → BUZZER level low. Factory default.
PROGRAM IN TO PA/SA OUT
SWITCH → LISTEN B.
LED BLINKING → The program input is sent to the PA output .
LED OFF → The program input is not sent to the PA output .
Factory default.
EF-202/EF-204 MASTER STATION - SERIE E-200
11
2
14
2
12
2
6
10
8
8
10
2730
30 27
2
2
6
2
8
8