Power Measurement
Eight power supply rails have on-board voltage and current sense capabilities. These 
measurements are made using an 8-channel differential A/D converter from Linear 
Technology, with a serial data bus connected to the MAX II CPLD. 
The MAX II CPLD contains a logic design that continually monitors the power rails 
and displays the current in mW on the dedicated four-digit 7-segment display. Rotary 
switch SW4 is used to select the power rail being displayed. The sense resistor is large 
enough that it can be easily probed by a user to confirm the display results. The 
results are also accessible from the FPGA through register access across the FSM bus. 
Figure 2–18 illustrates the circuit.
Ta bl e  2–16 on page 2–21 lists the power measurement rails. The Schematic Signal Name 
column lists the power rail being measured, and the power pins/devices attached to 
the power rail are listed in the Power Pin Name and Description columns. 
Statement of China-RoHS Compliance
Ta bl e  2–62 lists hazardous substances included with the kit.
Figure 2–18.  Power Measurement Circuit
MAX II Device 
SCK 
SDI 
SDO 
CSn 
A/D 
Load #1 
Load #13 
Supply #1 
R 
SENSE 
R 
SENSE 
Power Select 
Quad 7-segment 
Display 
16:1 
Analog 
Mux 
Amp 
Supply #13 
MAX II Control 
DIP Switch 
mA vs. mW 
Amps vs. Volts 
Table 2–62.  Table of Hazardous Substances’ Name and Concentration Notes (1), (2)  (Part 1 of 2)
Part Name Lead (Pb)
Cadmium 
(Cd)
Hexavalent 
Chromium 
(Cr6+)
Mercury 
(Hg)
Polybrominated
biphenyls (PBB)
Polybrominated
diphenyl Ethers 
(PBDE)
Cyclone III development board X* 0 0 0 0 0
12-V power supply 0 0 0 0 0 0
Type A-B USB cable 0 0 0 0 0 0