User guide
5–14 Chapter 5: Interlaken PHY IP Core
Interfaces
Altera Transceiver PHY IP Core March 2012 Altera Corporation
User Guide
0x042 [1:0]
WO
reset_control
 (write)
Writing a 1 to bit 0 initiates a TX digital reset using the reset 
controller module. The reset affects channels enabled in the 
reset_ch_bitmask. Writing a 1 to bit 1 initiates a RX 
digital reset of channels enabled in the 
reset_ch_bitmask.
R
reset_status
(read)
Reading bit 0 returns the status of the reset controller TX 
ready bit. Reading bit 1 returns the status of the reset 
controller RX ready bit.
Reset Controls –Manual Mode
0x044
—RW
reset_fine_control
You can use the 
reset_fine_control
 register to create 
your own reset sequence. The reset control module, 
illustrated in Figure 1–1 on page 1–2, performs a standard 
reset sequence at power on and whenever the 
phy_mgmt_clk_reset
 is asserted. Bits [31:4, 0] are 
reserved.
[3] RW
reset_rx_digital
Writing a 1 causes the RX digital reset signal to be asserted, 
resetting the RX digital channels enabled in 
reset_ch_bitmask. You must write a 0 to clear the 
reset condition.
[2] RW
reset_rx_analog
Writing a 1 causes the internal RX digital reset signal to be 
asserted, resetting the RX analog logic of all channels 
enabled in reset_ch_bitmask. You must write a 0 to 
clear the reset condition.
[1] RW
reset_tx_digital
Writing a 1 causes the internal TX digital reset signal to be 
asserted, resetting all channels enabled in 
reset_ch_bitmask. You must write a 0 to clear the 
reset condition.
PMA Control and Status Registers
0x061 [31:0] RW
phy
_
serial
_
loopback
Writing a 1 to channel <
n
> puts channel <
n
> in serial 
loopback mode. For information about pre- or 
post-CDRserial loopback modes, refer to “Loopback 
Modes” on page 10–39 .
0x064 [31:0] RW
pma_rx_set_locktodata
When set, programs the RX CDR PLL to lock to the 
incoming data. Bit <n> corresponds to channel <n>.
0x065 [31:0] RW
pma_rx_set_locktoref
When set, programs the RX CDR PLL to lock to the 
reference clock. Bit <n> corresponds to channel <n>.
0x066 [31:0] R
pma_rx_is_lockedtodata
When asserted, indicates that the RX CDR PLL is locked to 
the RX data, and that the RX CDR has changed from LTR to 
LTD mode. Bit <n> corresponds to channel <n>.
00x067 [31:0] R
pma_rx_is_lockedtoref
When asserted, indicates that the RX CDR PLL is locked to 
the reference clock. Bit <n> corresponds to channel <n>.
0x080 [31:0] RW
indirect_addr
Provides for indirect addressing of all PCS control and 
status registers. Use this register to specify the logical 
channel address of the PCS channel you want to access.
Table 5–12. Interlaken PHY Registers  (Part 2 of 3)  
Word 
Addr
Bits R/W Register Name Description