User guide

Chapter 9: Transceiver Reconfiguration Controller 9–3
Steps to Achieve PMA Controls Reconfiguration
December 2010 Altera Corporation Altera Transceiver PHY IP Core User Guide
Steps to Achieve PMA Controls Reconfiguration
You can use the Avalon-MM interface to change settings for the TX and RX channels.
Complete the following steps to reconfigure a setting:
1. Write the channel to be configured to the
logical
_
channel
_
address
.
2. Set the
tx_rx_word_offset
, indicating which PMA analog control is to be
changed.
3. Write the reconfiguration data to the
reconfig_data
register.
4. Set the
read
or
write
bit to 1.
5. Read the
busy
bit until it is deasserted, indicating that the operation has
completed.
0x10C
[15:0] RW
reconfig_data
Reconfiguration data.
[31:16] Reserved
0x110
eye_monitor
For complete information about the EyeQ interface and
registers refer to, “EyeQ Interface Register Mapping” in
the Stratix IV Dynamic Reconfiguration chapter in
volume 2 of the Stratix IV Device Handbook.
Table 9–1. Dynamic Reconfiguration Control and Status Registers (Part 2 of 2)
Offset Bits R/W Register Name Description