Following are additional commands commonly used with the MultiTasker:
Command/Format Action/Result
[GkUi] Returns feedback from a group. Example: ON12 G5U8
[RESUi] Resets MultiTasker enclosure, and all cards within it.
[VERCnUi] Displays the software version and card type of most (not all) cards
[IxOyCnUi] Matrix switch command: connects input “x” to output “y”
[SELmCnUi][+][+][+]... Adds one step per plus sign to multi-step range (Volume, Bright-
ness, etc.
[SELmCnUi][-][-][-]... Subtracts 1 step per minus sign from multi-step range (Volume,
Brightness, etc.)
[WRxxyyCnUi] Writes data “yy” to register “xx” in card “n” (used in more com-
plex cards)
As you can see, the MultiTasker command set is a robust, easy-to-use structure which can be
executed from any device capable of sending ASCII characters via RS-232.