User`s guide

MULTI-TASKER
7
2) [ON3C5U3]: Turns ON only output 3 of the
MT105-112/119 card located in slot #5 of the
MT100-100 Enclosure with unit ID3. After the
[ON12C5U3] and [ON3C5U3] commands have
been executed, output 1, 2 and 3 will be ON.
3)
[ONC5U3]: Turns ON all outputs of the card.
[ONmGkUiS]: for a group of cards
This command enables output "m" for each card
in group "k" of unit "i".
m = card output (m = # from 1-16)
k = group number (k = # from 1-9)
i = unit number (i = # from 0-9)
S = saves command to memory
Example:
1. [ON1G5U1]: Turns ON output 1 for each card
in group5 of unit 1.
2. [ONG5U1]: Turns ON all outputs for each card
in group5 of unit 1.
[ON…P]: sets path
This command will set the path for the output,
but it is not active until the switch command is
executed ( [SW] ). Commands ending in "P" are
not executed immediately. The path for outputs
on multiple cards or the same card can be
loaded.
Command Format: [ONmCnUiP]
m = Output number (m =1 to 16)
n = card ID No. (n = a slot # from 1 to 19) (1 to 8
for MT100-101 or 1 to 4 for MT100-106)
P = path
Example:
If 2 cards are at slot 4 and 8 of unit 3:
To enable output 1 and 2 of card 4 and output 3
and 4 of card 8 simultaneously, use the following
commands:
[ON12C4U3P]
[ON34C8U3P]
[SW]
If "F" is included use the [ONmCnUiPF]
command or the [ONmCnUiFP]
command.
[ON…F]: feedback
After processing a command, an OK or ER will
be returned as feedback if "F" is included at the
end of a command string or if the unit ID is zero.
Example:
[ON1C4U3F]: if path is not set
[ON1C4U3PF]: if path is set
6. [OFF]
This command disables output of single card or
a group of cards.
[OFFmCnUiS]: for a single card
This command disables output “m” without
affecting any other outputs.
m = output number (m = 1 to 16)
n = card ID No. (n = slot # from 1 to 19) (1 to 8
for MT100-101 or 1 to 4 for MT100-106)
i= Unit ID number (i = 0 to 9)
S = saves command to memory
[OFFCnUi]: Turns OFF all outputs of the card
Example:
1) If card 5 of unit 3 has output 1, 2 and 3 ON:
a)
[OFF1C5U3]: Turns OFF output 1 while output
2 and 3 remain ON.
b)
[OFF23C5]: Turns OFF output 2 and 3.
2) If card 5 of unit 3 has output 1, 2, 3, 4, 5, 6, 7
and 8 ON:
a)
[OFFC5U3]: Turns OFF all outputs, which is
equivalent to
[OFF12345678C5U3].
[OFFmGkUiS]: for a group of cards
This command disables output "m" for each card
in group "k" of unit "i".
Command Format: [OFFmCnUiP]
m = card output (m = # from 1-16)
k = group number (k = # from 1-9)
i = unit number (i = # from 0-9)
S = saves command to memory
Example:
1. [OFF1G5U1]: Turns OFF output 1 for each
card in group5 of unit 1.
2. [OFFG5U1]: Turns OFF all outputs for each
card in group5 of unit 1.
[OFF…P]: sets path
This command will set the path for the output,
but it is not active until the switch command is
executed ([SW]). Commands ending in "P" are
not executed immediately. The path for outputs