MULTITASKER® MANUAL PART NUMBER: 400-0372-005 MT107-303 8-OUT, TWISTED PAIR, SINGLE CHANNEL OUTPUT CARD FOR MATRIX SWITCHER USER’S GUIDE
MULTITASKER TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS................ 2 GENERAL..........................................................2 INSTALLATION..................................................2 CLEANING.........................................................2 FCC NOTICE .....................................................2 ABOUT YOUR MT107-303....................................... 3 TECHNICAL SPECIFICATIONS.............................. 3 PRODUCT DESCRIPTION ..........................
MULTITASKER PRECAUTIONS / SAFETY WARNINGS • 1 Please read this manual carefully before using your MT107-303. Keep this manual handy for future reference. These safety instructions are to ensure the long life of your MT107-303 and to prevent fire and shock hazards. Please read them carefully and heed all warnings. 1.1 GENERAL • Qualified ALTINEX service personnel or their authorized representatives must perform all service. 1.
MULTITASKER ABOUT YOUR MT107-303 2 TECHNICAL SPECIFICATIONS Specifications are subject to change. See www.altinex.com for up-to-date information. MT107-303 8-Out, Twisted Pair, Single Channel FEATURES/ DESCRIPTION GENERAL Input Twisted Pair Output Connectors Twisted Pair Compatibility The MT107-303 is an 8 Output expansion card for use with the MT107-104 64X64 Matrix Engine. The MT107-303 outputs are single channel differential outputs for use over long cable lengths.
MULTITASKER ELECTRICAL MT107-303 Output Twisted Pair Video/Sync/Audio Signals ALTINEX Standard Analog Signal Level 1.5 Vp-p max. Input Bus from Matrix Engine Power Consumption 0 dB gain (from enclosure) +6V 0.225 A (1.3 W) -6V 0.190 A (1.1 W) Total Power 2.4 W max. Table 3.
MULTITASKER PRODUCT DESCRIPTION 4 8 1TP OUTPUTS BOTTOM RETAINER SCREW 400-0372-005 5
MULTITASKER APPLICATION DIAGRAMS 5 DIAGRAM 1: TYPICAL SETUP MT107-303 MS 87 04 TP DA 19 31 CT MS 87 04 TP DA 400-0372-005 19 31 CT 6
MULTITASKER DIAGRAM 2: INTERNAL VIEW POWER INPUT 40-PIN IDC IN1 OUT1 IN2 OUT2 IN3 OUT3 IN4 OUT4 TWISTED PAIR RJ-45 IN5 OUT5 IN6 OUT6 IN7 OUT7 IN8 OUT8 SIGNAL DETECT 400-0372-005 7
MULTITASKER INSTALLING YOUR MT107-303 6 OPERATION Step 1. Turn off power to the MultiTasker enclosure and remove the input AC power cord. 7.1 RS-232 CONTROL The MT107-303 has many advanced remote-control capabilities as part of an MT107-104 Matrix Switcher. These capabilities are accessible through standard RS-232 communication. The actual controlling can be accomplished through a computer control system or any other device capable of sending RS-232 commands. Step 2.
MULTITASKER Cause 3: The path is not selected. ALTINEX POLICIES Solution: Make sure the input to output path is correctly selected. 9.1 LIMITED WARRANTY/RETURN POLICIES Please see the ALTINEX website at www.altinex.com for details on warranty and return policies. For example, Input 2 is connected to Output 1 in the Matrix Engine status. Physically, the source signal should be connected to Input 2 and the display cable should be connected to Output 1.