User`s guide

MULTI-TASKERâ„¢
8
Cause 3: The path is not selected.
Solution: Make sure the input to output path is
correctly selected.
For example, Input 17 is connected
to Output 1 in the matrix engine.
Physically, the source signal should
be connected to Input 17 and the
receiving cable should be connected
to Output 1. See RS-232 accessible
commands in Section 7 of the
MT107-100/104's User Guide for
command details.
If the devices still fail to function
properly, see Cause 4.
Cause 4: Cable connections are incorrect.
Solution: Make sure that cables are properly
connected. Also, make sure that the
continuity and wiring are good. If the
are still not functioning, see
Cause 5.
Cause 5: The transmitting or receiving
device has a problem.
Solution: Make sure the receiving DA1934KM
and Transmitting DA1935KM have
power and are properly connected.
If there is still no response, please
call Altinex at (714) 990-2300.
ALTINEX POLICY 9
9.1 LIMITED WARRANTY/RETURN POLICY
Please see the Altinex website at
www.altinex.com
for details on warranty and
return policy.
9.2 CONTACT INFORMATION
ALTINEX, INC
592 Apollo street
Brea, CA 92821 USA
TEL: 714 990-2300
TOLL FREE: 1-800-ALTINEX
WEB: www.altinex.com
E-MAIL: solutions@altinex.com