User`s guide

MULTI-TASKER
15
15
To save setting loudness on card in slot 10 send
command [SLVC10U1].
21. [WR….GkUi]
This command groups multiple cards in the
MT100-100 Enclosure. Each unit contains a
maximum of nine groups. Command Format:
[WRCn…GkUi]
n = card ID No. (n = slot # from 1 to 19)
k = group number (k = # from 1-9)
i = unit number (i = # from 0-9)
Example:
To group card #1, 2, and 3 as group 5 of unit
#1, send the [WRC1C2C3G5U1] command.
After executing this command, cards 1, 2, and 3
of unit 1 will be grouped together as group 5.
22. [CLR]
This command clears the members for a single
group or for all nine groups. Command Format:
[CLRGkUi]
k = group number (k = # from 1-9)
i = unit number (i = # from 0-9)
Example:
a) To clear group #1, send the [CLRG1U1]
command. This command clears the members
for the specified group only.
b) b) To clear all groups of unit 1, send the [CLR
G....U1] command.
23. [GkUi]
This command is used to request group data.
With the command, the user can identify which
input or output of a particular group is on.
Command Format: [GkUi]
k = group number (k = # from 1-9)
i = unit number (i = # from 0-9)
Example:
If group 1 has DA Cards with output 1 and 2 on,
while group 2 has SW Cards with input 2 on:
1) [G1]: will return feedback as [On12G1].
2) [G2]: will return feedback as [On2G2].
24. [RDXX]
This command reads card memory at address
XX . Command Format: [RDXXCnUi]
XX = data address (XX = # from 60-FF in hex
format)
n = card ID No. (n = slot # from 1 to 19)
i = unit number (i = # from 0-9)
Example:
To read memory at address 0x0A card 2 of unit
1, send the [RD0AC2U1] command. The system
will return feedback as RD0A1DC2, if data at
address 0x0A is 0x1D.
25. [WRXXYY]
This command writes data YY into card memory
at address XX . Command Format:
[RDXXYYCnUi]
XX = data address (XX = # from 60-FF in hex
format)
YY = data (YY = # from 00-FF in hex format)
n = card ID No. (n = slot # from 1 to 19)
i = unit number (i = # from 0-9)
Example:
To write data 0x2B into memory at address
0x10 card 5 of unit 1, send the [RD102BC5U1]
command. The system will return feedback as
OK.
26. [WRCn…GkUi]
This command groups multiple cards in the
MT100-100 Enclosure. Each unit contains a
maximum of nine groups.
n = card ID No. (n = slot # from 1 to 19)
k = group number (k = # from 1-9)
i = unit number (i = # from 0-9)
Example:
To group card #1, 2, and 3 as group 5 of unit
#1, send the [WRC1C2C3G5U1] command.
After executing this command, cards 1, 2, and
3 of unit 1 will be grouped together as group 5.
27. [CLRGkUi]
This command clears the members for a single
group or for all nine groups.
Command Format: [CLRGkUi]
k = group number (k = # from 1-9)
i = unit number (i = # from 0-9)