User`s guide

SPECIAL APPLICATION
400-0384-002
24
Command Format: [SETMD=xCi]
x = Trigger Level (x = # from 01 to 50)
01 = 0.1V
02 = 0.2V
50 = 5.0V
Ci = Unit ID (i = # from 1 to 99)
Example:
Set the trigger level a value of 1.0V by sending
the command [SETMD=10]. Use the [RDMD]
command to read values and check settings.
61. [SETTMD]
This command sets the motion detector time
delay. The sensor will trigger until a target is
found and then stop sensing and not check for a
new target until after the specified delay time.
The range is 01 to 99, where each increment is
0.1 minutes and the minimum delay time is
6 seconds.
Command Format: [SETMD=xCi]
x = Time Delay (x = # from 01 to 99)
01 = 0.1 minutes (6 sec)
02 = 0.2 minutes (12 sec)
99 = 9.9 minutes
Ci = Unit ID (i = # from 1 to 99)
Example:
Set the time delay to a value of one minute by
sending the command [SETTMD=10]. Use the
[RDMD] command to read values and check
settings.
62. [MDTYPE]
This command sets the motion detector time
delay. The sensor will trigger until a target is
found and then stop sensing and not check for a
new target until after the specified delay time.
The range is 01 to 99, where each increment is
0.1 minutes and the minimum delay time is
6 seconds.
Command Format: [MDTYPE=xCi]
x = Sensor Type (x = 0 or 1)
0 = Ultrasound Motion Detector
1 = PIR Motion Detector
Ci = Unit ID (i = # from 1 to 99)
Example:
Set the time delay to a value of one minute by
sending the command [SETTMD=10]. Use the
[RDMD] command to read values and check
settings.
63. [RDMD]
Use this command to display the motion
detector settings and check its status. The
status includes the settings, assigned
subroutines, current detected reading and
whether or not the motion detector is active.
Command Format: [RDMDCi]
Ci = Unit ID (i = # from 1 to 99)
Example:
The motion detector trigger level is set to 1.0V,
subroutine 10 is assigned for objects moving
away from the detector, subroutine 11 is
assigned for objects moving toward the
detector. Send the command [RDMD] and
receive feedback similar to the following:
Motion Detector ON
MD Current value:04
MD Threshold value:10
MD0=SUB10
MD1=SUB11
ID COMMANDS RSI, SIDn, SIDnCi, RSN
64. [RSI]
This command resets the card ID's in the
system. After sending this command, each card
ID will be ‘0’.
Command Format: [RSI]
Example:
Send the command [RSI] to the system with
ID 2. The card can no longer be recognized as
ID 2, it will be ID 0.