36) [ALRMON] Activate Alarm.
37) [ALRMOFF] Deactivate Alarm.
38) [RDALRM] Read alarm settings.
39) [ALRMn=SUBk] Set Alarm Dependencies.
40) [WRM] Save RS-232 data.
41) [WRLM] Write memory label.
42) [RDM] Display memory data.
43) [RDLM] Display memory label.
44) [CLRM] Clears memory location.
45) [CLRLM] Clears memory label.
46) [MODERSI] Set internal baud rate.
47) [RDRSI] Read internal baud rate.
48) [OUTRSM] Memory via RS-232 ext.
49) [OUTBSM] Memory via RS-232 int.
50) [OUTPDPM] Memory to plasma main.
51) [OUTVCM] Memory to plasma video.
52) [SENDRS] Send data via external bus.
53) [SENDBS] Sends data via internal bus.
54) [SENDPS] Send data to display card.
55) [SENDVS] Send data to video card.
56) [MDON] Motion detector enabled.
57) [MDOFF] Motion detector disabled.
58) [MD1] Set approaching motion.
59) [MD0] Set departing motion.
60) [SETMD] Set detector trigger value.
61) [SETTMD] Set detector time delay.
62) [MDTYPE] Detector type.
63) [RDMD] Read motion det. settings.
64) [RSI] Reset card ID.
65) [SIDn] Set ID of cards.
66) [SIDnCi] Set ID of a single card.
67) [RSN] Read ID number.
7.4 PLASMA CONTROL WITH INTERNAL BUS
The PE1005 has the capability of sending
commands directly to the plasma’s internal bus or
to third party video cards installed in the plasma.
This allows the user to control settings on the
display without having to use the menu buttons on
the display or with the remote control.
As in the previous sections, the commands are
sent through standard RS-232 communication.
Commands may be sent directly to the internal bus
or stored into RS memory locations and then
recalled from the memory location and sent to the
bus. The commands for communicating with the
internal bus are [OUTPDPM] and [SENDBS]. See
the previous sections for details on these two
commands, including restrictions on the number of
character that may be stored or sent in a single
command.
7.4.1 INTERNAL COMMAND FORMAT
The internal commands, for the PE1005, are in
the following format and must contain the
protocols indicated:
1. Start of text. (STX) %02
2. Plasma ID (default) %2A%2A
3. Command ID See Appendix A.
4. End of text. (ETX) %03
7.4.2 SENDING COMMANDS TO INTERNAL BUS
The default baud rate for the PE1005 is 9600
baud. Prior to sending any commands, verify
both the plasma and PE1005 are set to 9600
baud.
In order to change setting values, the plasma
must be in adjustment mode. The plasma may
be placed into adjustment mode by sending the
command AJY.
The following examples demonstrate
communication with the plasma through the
internal bus using both stored commands and