User's Manual

Installing the iRU4438 iRRH
iRU4438 iRRH Product Descripton and Installation Guide 5-9
NOTE
The wall where the iRU4438 iRRH is to be mounted must be able to
support four times the weight of the unit. The unit can be mounted at a
deviation from vertical of 10°.
NOTE
The mounting clamp is not used when mounting the iRU4438 iRRH to a
wall or other flat surface. In addition, the M12 bolts supplied in the
hardware kit are not used for wall-mount applications.
NOTE
The Operator must provide two (2) M12 anchors, designed for outdoor
use, that are compatible with the type structure on which the iRRH is to
be installed.
To install mounting plate on a wall:
1. Determine the location where the mounting bracket is to be installed.
NOTE
The center-to-center distance for drilling holes to install the selected
anchor is 5.5 in (140 mm).
2. Using a tape measure and spirit level, mark where the anchor will be installed
using a center punch.
3. Drill the holes where the fastener will be installed on the wall using a drill bit sized
for the fastener.
4. Install the iRRH mounting bracket to the wall using the two (2) M12 anchor bolts
selected and supplied by the Operator, two (2) washers and two (2) lock washers
supplied with the mounting hardware.
5. Tighten the bolts as specified by the M12 anchor's manufacturer using a torque
wrench.
5.6 Hoisting the iRU4438 iRRH on elevated structures
Hoist line and tag line lift points are provided on the iRU4438 iRRH. These are the
ONLY recommended locations of attachment when hoisting and guiding the iRRH into
position on elevated structures. Carabiners should be used at both the hoist and tag