Specifications
-
Smart-Track® 2-circuit specification
The Track Lighting System shall consist of high quality aluminum extruded lighting track with
integral data distribution, rugged multi adapters to support fixtures & transfer power/ data from
the track to controllable devices such as lighting fixtures. It shall be possible to field cut Track
Sections to necessary lengths for each project and location. The top of the track shall have an
extruded profile to allow for the mounting a manufacturer supplied bracket/ hanging supports
for connecting with contractor supplied stem, cable or threaded rod. Track Sections shall
distribute (2) 20amp 120vAC power circuits with independent Neutrals and shall include integral
distribution of DMX-512A (ANSI E.1.11-2004) and RDM (ANSI E1.20-2006) control signals to
lighting fixtures and controllable devices mounted on the Smart Track.
Connection points shall be available for both wired and wireless connection of controls to the
Lighting System. The Lighting System shall have a complete line of components to join data
and electrify separate track pieces, including: Live End Feeds, Dead End Caps, InǦLine
Couplers, Feed Thru Connectors, L Turns (left and right), Flexible Couplers, X & T-Connectors,
& Data Terminators.
All components of the Lighting System shall be U.L. or ETL listed
-
Smart-Track® luminaire specification
Fixtures for use on the DMX track system shall include an onǦboard DMX interface and an in-
stalled Multi- Adapter designed to mechanically hang, power and feed data. Fixtures compati-
ble with the Lighting System shall include incandescent, low voltage, CDM, and LED sources.
Luminaires shall be compatible with DMX-512A (ANSI E.1.11-2004) and RDM (ANSI E1.20-
2006) control protocols. LED color changing luminaires shall be available as two types; fixed
color temperature white or color mixing (RGBA). LED fixtures shall feature integral power
supplies, drivers, pre-programmed modes and DMX interface. Quartz fixtures shall have an
integral, onǦboard DMX controlled phase-forward (leading edge) dimmer compatible with
incandescent, low voltage, and certain phase-dimmable LED loads. Metal Halide (CDM)
fixtures shall have an onǦboard DMX on/off relay rated for a maximum of 70 watts.
DMX addressing for all system fixtures shall be conducted via either a) manual setting of the
rotary dials for Dimmer & CDM luminaires and a push button display for LED or b) RDM from a
remote location by a compatible hand held programmer or personal computer. Luminaires shall
be supplied with two dip switches to change modes from DMX , DMX/ RDM, manual over ride
dimmer control, and full on power mode. All fixture dip switches and dials will be concealed by
a latch that requires the use of a screwdriver to access and make changes. Luminares shall
retain their identity and programming, even when moved to a new location. Data input on all
fixtures shall have high voltage protection circuitry. Fixtures may be connected to the system
at any point along the track. All fixtures shall be U.L. or ETL listed.
!!!"#$%&#'$()*%(')"+,&-