Specifications
MN-28664 • Rev 3 (07/14) • ASC-4G Gas Convection Oven - Manual Control • 8
INSTALLATION
This appliance is equipped with a three-prong 
grounding plug. For your protection against shock 
hazard this appliance should be plugged directly into 
a properly grounded three-prong receptacle. Do not 
cut or remove the grounding prong from this plug.
Plug the unit into a properly grounded receptacle 
ONLY, positioning the unit so that the plug is easily 
accessible in case of an emergency. Arcing will occur 
when connecting or disconnecting the unit unless all 
controls are in the “off” position.
Proper receptacle or outlet configuration or 
permanent wiring for this unit must be installed by 
a licensed electrician in accordance with applicable 
local electrical codes.
ELECTRICAL CONNECTION 
 DANGER
ENSURE POWER SOURCE 
MATCHES VOLTAGE IDENTIFIED 
ON APPLIANCE RATING TAG.
DANGER
To avoid electrical shock, this 
appliance MUST be adequately 
grounded in accordance with local 
electrical codes or, in the absence of 
local codes, with the current edition 
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical 
connections are to be made in 
accordance with CSA C22.1, Canadian 
Electrical Code Part 1 or local codes.
ELECTRICAL
VOL TAGE PHASE CYCLE/H Z AMPS KW
120 1 60 7.5 0.9
9' (2743mm) cord with plug included: NEMA 5-15P