Technical data

#6001 COMBITHERM ELECTRIC INSTALLATION AND MAINTENANCE MANUAL
PG. 24
PRESS THE ON/OFF POWER KEY TO THE ON POSITION.
THE WATER IN THE STEAM GENERATOR WILL BEGIN TO
HEAT. ALLOW THE OVEN TO REMAIN IN THIS
POSITION FOR A MINIMUM PERIOD OF
10 MINUTES TO DECALCIFY THE STEAM GENERATOR.
In the case of extreme calcification build-up such as in areas with very hard water, ovens can be left in
this condition overnight. Follow the remaining instructions at the start of the next production day.
This procedure will help keep the oven operating at peak efficiency.
After a period of 10 minutes or longer
PRESS THE ON/OFF POWER KEY TO THE OFF POSITION.
6. USING HAND PROTECTION, rotate the Steam Generator Drain Cap until water begins to flow from the
four holes in the cap. In approximately 20 to 60 seconds, a sufficient quantity of water will have drained
from the steam generator so that the drain cap can be completely removed. Let the water continue to drain
until the flow completely subsides.
7. Open the oven door. Loosen the thumb screw(s) and swing Fan Guard Cover Plate toward the back of
the oven. Using the hand-held hose, direct a stream of water directly into the Steam Exit Port several
times. Close the swing-out Cover Plate . Lock the cover into place and tighten thumb screw(s). Close
the oven door.
PRESS THE ON/OFF POWER KEY TO THE ON POSITION.
PRESS THE STEAM MODE KEY.
A new supply of fresh water will begin to fill the steam generator and will flush out all remaining
vinegar from the steam generator.
AFTER JUST 2 MINUTES OF OPERATION IN THE STEAM MODE, PRESS THE START/STOP KEY. ANY ADDITIONAL
LENGTH OF TIME WILL RESULT IN A LOW WATER ERROR OCCURRENCE.
PRESS THE ON/OFF POWER KEY TO THE OFF POSITION AND OPEN THE OVEN DOOR.
8. USING HAND PROTECTION, replace the Steam Generator Drain Cap by turning it clockwise until there
is a slight resistance. At the end of the production day, leave the door slightly ajar.
DO NOT COOK IN ANY PROGRAM MODE
WITH VINEGAR IN THE STEAM GENERATOR SYSTEM.
DURING DECALCIFICATION THE WATER FLOWING FROM THE DRAIN CAP IS
EXTREMELY HOT! USE HAND PROTECTION WHEN TOUCHING THE STEAM
GENERATOR DRAIN CAP. DO NOT TOUCH THE WATER FLOWING OUT OF THE
STEAM GENERATOR DRAIN CAP OR STEAM GENERATOR DRAIN.
COMBITHERM
®
DECALCIFICATION
STANDARD CONTROL