PROCESSING FREEZER / CHILLER / REFRIGERATION SYSTEM Model: QC2-3 QC2-20 QC2-40 QC2-100 QC2-100 remote QC2-100 QC2-40 • Installation • Operation QC2-3 • Maintenance W164 n9221 Water street • p.o. Box 450 • menomonee Falls, Wisconsin 53052-0450 Usa PHONE: 262.251.3800 • 800.558.8744 usa / canada FAX: 262.251.7067 • 800.329.8744 u . s . a . www.alto-shaam.com printed in u.s.a. only MN-29647 (Rev.
Delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Safety Procedures and Precautions. . . . . . . . . . . . . . . . . 2 Installation Site Installation. . . . . . . . . . . . . . . . . . . . . . . Clearance Requirements. . . . . . . . . . . . . . . .
deLiVery unpacKing This Alto-Shaam appliance has been thoroughly tested and inspected to insure only the highest quality unit is provided. Upon receipt, check for any possible shipping damage and report it at once to the delivering carrier. See Transportation Damage and Claims section located in this manual. This appliance, complete with unattached items and accessories, may have been delivered in one or more packages.
safety procedures and precautions Knowledge of proper procedures is essential to the safe operation of electrically and/or gas energized equipment. In accordance with generally accepted product safety labeling guidelines for potential hazards, the following signal words and symbols may be used throughout this manual. danger Used to indicate the presence of a hazard that WILL cause severe personal injury, death, or substantial property damage if the warning included with this symbol is ignored.
i n st a l l a ti o n danger IMPROPER INSTALLATION, ALTERATION, ADJUSTMENT, SERVICE, OR MAINTENANCE COULD RESULT IN SEVERE INJURY, DEATH, OR CAUSE PROPERTY DAMAGE. READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT. caution TO PREVENT PERSONAL INJURY, USE CAUTION WHEN MOVING OR LEVELING THIS APPLIANCE. 5-Year Limited Warranty on self-contained compressor Effective from date of shipment.
i n st a l l a ti o n sit e i n st a l l a ti o n I N ST ALLA T ION REQ U IRE MEN TS The model QC2-3 is a counter mounted unit and must use legs that allow for a 4" (102mm) clearance between the cabinet and the counter. For all other models, install the appliance on a smooth and level floor surface. Use the adjustable cabinet legs to level the Quickchiller.
i n st a l l a ti o n sit e i n st a l l a ti o n W A T ER DRA I NAGE A 1" NPS drain is located under the QC2-100. Connect the drain pipe using Teflon tape to discharge through an indirect waste pipe into an open-site drain by means of a 2" (51mm) air gap. Connection must be within 10' (3m) of the unit. NOTE: I n the U.S.A., this equipment is to be installed to comply with the Basic Plumbing Code of the Building Officials and Cod e Administrators International, Inc.
i n sttit a l llaeti o n sube tit sit i n st l ea l l a ti o n QC2-3 10-1/4" (260mm) Electrical Connection 35-1/4" (895mm) with caster option ALTO SHAAM 39" (991mm) with standard leg 55-3/4" (1416mm) 5" (127mm) Electrical Connection Cord Length: 9' (2743mm) 30" (762mm) 27" (686mm) weig h t produ ct\pan capacity net : contact factory carton dimensions : ( l ship : Approximately 36 lb (16 kg) 330 lb (150 kg) volume maximum : x w x h) 35" x 35" x 42" (889mm x 889mm x 1067mm) refr i ge r ati on
I N S Ttit ALLA l eT I O N sube tit sit i n st l ea l l a ti o n 36" (914mm) 57" (1448mm) 36" (914mm) 36" (914mm) 42" (1067mm) 60" (1524mm) QC2-20 Cord Length 9' (2743mm) weig h t produ ct\pan capacity net : contact factory carton dimensions : ( l ship : 450 lb (204 kg) x w x h) 60" x 39" x 48-1/2" (1524mm x 991mm x 1232mm) refr i ge r ati on 40 oz.
I N S Ttit ALLA l eT I O N sube tit sit i n st l ea l l a ti o n QC2-40 After June 2012 44" (1118mm) 34-1/2" (877mm) 68-9/16" (1741mm) 20-1/2" (521mm) Electrical Connection Cord Length 9 ft (2743mm) ALTO SHAAM 75" (1905mm) 75" (1905mm) ALTO SHAAM 34" (864mm) 7" (178mm) Electrical Connection Cord Length 9 ft (2743mm) 34" (864mm) 26-7/16" (671mm) 60-7/16" (1534mm) 7" (178mm) Electrical Connection Cord Length 9 ft (2743mm) 20-1/2" (521mm) Electrical Connection Cord Length 9 ft (2743mm) Prior to J
I N S Ttit ALLA l eT I O N sube tit sit i n st l ea l l a ti o n QC2-100 35-1/2" (902mm) Electrical Connection Condensate Drain 40" (1015mm) 75-1/2" (1917mm) 14" (355mm) 17-5/8" (447mm) 15-1/2" (394mm) Hinged Left 35-1/2" (902mm) Hinged Right 51" (1294mm) weig ht QC2-100 net : 1000 lb (454 kg) ship : Pan Cart net : 120 lb (54 kg) ship : Plate Cart net : contact factory carton dimensions : ( l 1186 lb (538 kg) est 161 lb (73 kg) ship : contact factory x w x h) 57" x 44" x 94" (1448mm
I N S Ttit ALLA l eT I O N sube tit sit i n st l ea l l a ti o n QC2-100R 35-1/2" (902mm) Electrical Connection Condensate Drain 40" (1015mm) 75-1/2" (1917mm) 14" (355mm) 17-5/8" (447mm) 15-1/2" (394mm) Hinged Left 35-1/2" (902mm) Hinged Right 51" (1294mm) weig ht QC2-100R Pan Cart net : contact factory net : Plate Cart 120 lb (54 kg) net : contact factory carton dimensions : ( l ship : contact factory ship : 161 lb (73 kg) ship : contact factory x w x h) 57" x 44" x 93" (1448mm x 1118m
I N S Ttit ALLA l eT I O N sub o p ti otit n sl ea n d a c c e ss o r i e s model > Casters, 3" (76mm) [ set of Casters, 5" (127mm) [ set 4] of 4] HACCP Documentation, Data Logger •O n-board Datalogger technology maintains accurate and timely recordkeeping • Register start time and end time • Register start temperature and end temperature • I nterim time and temperature reporting is captured at 5 minute intervals •U SB downloads facilitate record keeping on department management PC's •E lectron
i n sttit a l llaeti o n esub l e c tit t r ilcea l This appliance must be branch circuit protected with proper ampacities, in accordance with the wiring diagram. The Quickchiller must be properly grounded in accordance with the National Electrical Code and applicable local codes. Wire size for the main incoming power to the unit must match the minimum size listed in the specifications applicable to the specific Quickchiller model. For supply connections, locate the wire size listed in this manual.
O p etit r alti e on OPERA T I NG I N T RO DUCTION The Alto-Shaam ® Quickchiller ™ is a processing refrigeration system designed to rapidly and uniformly decrease the temperature of hot foods to either a chilled or frozen state. This process provides enhanced safety, longer storage life and better production efficiency.
O p etit r alti e on CHILL PROCESSING CYCLES Quickchiller Operation Modes The Alto-Shaam Quickchiller uses high velocity cold air circulation to remove heat from prepared foods for the purpose of rapidly reducing temperatures through the danger zone and providing maximum storage life. Cold air is evenly directed across each pan from the control side of every Quickchiller model to assure rapid cooling.
O p etit r alti e on Additional information Fan operation ➤ Clean the Quickchiller and probes prior to use and make certain all processing modes are operating properly before chilling or freezing foods. During the initial cooling of the Quickchiller, an evaporator fan delay system will prevent the chilling fans from engaging until the evaporator coil temperature is below 30°F (-1°C). The fans will continue to run until the evaporator coil temperature is above 60°F (16°C).
O p etit r alti e on CO N T R OL P AN EL I DE NT I F I C A T I O N A B C on / off power button . soft chill … To rapidly decrease the temperature of foods by internal product probe temperature or time within a range of 24°F to 36°F (-4°C to 2°C). Soft Chill is recommended for less dense food items that chill quickly. The mode automatically converts to a refrigerated holding temperature at the end of the chill cycle.
O p etit r alti e on sub b a si c titolpee r a ti o n tarting from the S power key on . 1. off position, press the The Alto-Shaam name will illuminate and the Selection screen will appear on the display. The compressor will become energized and will begin to operate if required by the sensors. 2. Press the desired mode key. Mode will operate at last settings entered. a. Soft Chill - Select Soft Chill for less dense items such as fish or vegetables. b.
O p etit r alti e on sub a dv atit n c le ed o p e r a ti o n The date and time will appear in the display when the unit is off. When the unit is turned on, the screen will read: “SELECT MODE OR PRESS START TO SELECT PRESET” To initiate any Quickchiller operating mode, power must initially start from the off position or an operating mode must be halted by pressing the Start/STOP key so that the Selection screen appears on the display.
O p etit r alti e on sub a dv atit n c le ed o p e r a ti o n QU IC K FR E E Z E, HA R D C HI L L , S O F T CH ILL manual operation 1. tarting from the S power key on . off position, press the The Alto-Shaam name will illuminate and the Selection screen will appear on the display. The compressor will become energized and will begin to operate if required by the sensors. 2. Press the desired mode key. The display will give an overview of the current set-temperatures for the mode.
O p e r a ti o n a dv a n c e d o p e r a ti o n — p r e s e t p r o g r a mmi n g PRE S E T PROGRA M OPERATION PROGRAMMING PRESET S 1. S tarting from the off position, press the power key on . The Alto-Shaam name will illuminate and the Selection screen will appear on the display. The compressor will become energized and will begin to operate if required by the sensors. 1. S tarting from the off position, press the power key on .
O p etit r alti e on sub a dv atit n c le ed o p e r a ti o n – U S ER S E T T I NG S CHANGING USER SETTINGS tarting from the off position, press the power S key on. The Alto-Shaam name will illuminate and the Selection screen will appear on the display. The compressor will become energized and will begin to operate if required by the sensors. Press the Program key. The display will indicate the User Settings each time the Program key is pressed. USER SETTINGS 1. Start Manual Defrost 8. HACCP Download 2.
O p etit r alti e on sub a dv atit n c le ed o p e r a ti o n – U S ER S E T T I NG S 8. HACCP Download (only on units with optional HACCP Datalogger) Insert USB data stick into data port on front of the unit. Display will indicate USB. Press the Program key and then press the down6arrow key until "HACCP Download" is selected. Press the Start/Stop key. Display will indicate USB and the % status copied to USB data stick. When 100% is displayed, transfer is complete.
O p e r a ti o n a dv a n c e d o p e r a ti o n – U S ER S E T T I NG S 12. defrost time (minutes) 9. PROBE VERIFICATION With the probe verification selected, press the Start key to enter the probe verification mode. The offset and the temperature will display for: Top Probe (where applicable) Middle Probe (where applicable) Bottom Probe (where applicable) If probe calibration is needed, place the probe in a glass of ice-water and let the probe settle in temperature.
O p etit r alti e on Food Probe Use user information Unpacking Food Probes 1. Cut and remove the plastic ties keeping the probe cables coiled during shipment. When removing the ties, exercise caution to avoid accidentally cutting the black plastic covers on the probe cable wires. 2. Uncoil the probe cables and insert the metal portion of each probe into the bracket mounted on the inside of the cabinet.
O p etit r alti e on sub Dtit FOO HAN l e D L I NG G U I D EL I NE S P r o duc t c o v e r in g PORT IONING & PACKAGING To maintain sanitation control when loading the Quickchiller, foods should be above 140°F (60°C) and should be tightly covered. A tight cover is an important part of proper chilling methods and must be used to prevent the possibility of accidental contamination by airborne bacteria. 1.
O p etit r alti e on Q uic k c h i l l e r Pa n Cap a c it y: The following Quickchiller Capacity Chart indicates the number of pans that can be accommodated in the appropriate size chiller for the chilling or freezing function. Additional pans can be accommodated only when using the Quickchiller for holding at a refrigerated temperature or at a maintenance temperature for frozen food. DO NOT OVERLOAD THE QUICKCHILLER FOR THE PROCESSING FUNCTION. c h i l l i n g PAN C a p a c it y CHAR T chiller no .
O p etit r alti e on the following chart of portion sizes and SERVING capacitY PER PAN IS PROVIDED as a general reference ONLY.
c a r e a ntit d lcel e a n i n g cLeaning and preVentatiVe maintenance protecting stainLess steeL surfaces It is important to guard against corrosion in the care of stainless steel surfaces. Harsh, corrosive, cLeaning agents Use non-abrasive cleaning products designed for use on stainless steel surfaces. Cleaning agents must be chloride-free compounds and must not or inappropriate chemicals can completely destroy the contain quaternary salts.
c a r e a ntit d lcel e a n i n g Interior Cleaning Probe Cleaning Procedures Remove the optional roll-in cart (trolley) from cart equipped models. Open the Quickchiller door to warm the interior of the cabinet. 1. Remove all food soil from probes between loads and at the end of each production shift. Wipe entire probe, cable assembly, and probe holding door bracket with warm detergent solution and a clean cloth. 2.
t r o ub ltit e slheo o ti n g CON T ROL ERROR DI S PLAYS control display action required Real Time Clock Bad This is likely caused by the unit having been unplugged for an extended amount of time. The data stored in the Real-Time Clock has been reset to the factory default values. Contact service if problem persists. E-60: REAL TIME CLOCK DEFAULTS LOADED, VERIFY CORRECT TIME, POWER CYCLE UNIT TO CLEAR THIS MESSAGE. Real Time Clock Not Detected Real Time Clock not detected.
parts information QC2-3 Bottom 12 13 14 11 1 10 2 9 5 8 7 4 3 5 6 Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Part RE-29821 PE-29819 PE-29830 SW-29823 LG-29904 CS-29822 SC-29824 BX-29820 SC-29829 FU-29901 PN-29825 EL-29828 NU-29827 BT-29826 CD-29831 Description Condensing Unit Duct Top Louver Channel Compressor Louver Pressure Switch 6" (152mm) Leg, Standard 3" (76mm) Ranserve Caster Non Locking, Option Bolt, 1/4-20 x 3.
parts information QC2-3 Box view 2 1 21 3 4 20 5 6 7 19 8 18 17 16 4 9 15 10 14 Item 1 2 3 4 5 6 7 8 9 10 11 12 Part BT-29841 PR-34299 PR-34298 SR-29832 BU-29937 SC-29839 GS-29838 DR-29833 HG-29959 PI-35930 SC-29835 HG-29834 Description Holding Bracket Ref Line Probe Receptacle Assembly Probe, Quick Connect Stainless Steel Side Rack Bushing, Nylon Hinge 118 Screw, 10x1/2" Slot Gasket, 15.59 x 24.
parts information QC2-3 coil view 1 2 3 4 5 7 6 8 9 6 Add plastic edge guard to drip pan 15 16 Item 1 2 3 4 5 6 7 8 Part GD-29848 GD-29850 FA-29854 FA-29853 SC-29855 BT-29847 VA-29852 RE-29846 Description Qty.
parts information QC2-3 Compressor view 2 3 1 4 7 6 5 4 Item 1 2 3 4 5 6 7 Part RE-29861 SW-29823 FI-29862 VA-29863 VA-29864 MO-29865 FA-29866 Description Condensing Assembly, 1/2 MED R404A 120V Pressure Switch Dryer, 1/4" Filter with 2nd 1/4" Solenoid Valve & 120V Coil Valve, Sporlan CRO-4-0/75 Crankcase Pressure Reg. Motor, Fan Condenser Unit Fan Blade 1/4" & 3/8" Diameter Copper Tubing is used QUICKCHILLER PARTS • MN-29647 (REV. 0) • INSTALLATION/OPERATION/SERVICE MANUAL • 34. Qty.
parts information QC2-3 ContRol Box 1 3 2 4 8 7 6 9 5 1 18 17 15 16 10 11 14 13 12 Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19* 20* Part BT-29929 BA-34010 BA-34009 BT-29918 CR-29925 FU-29934 BK-29919 CR-29924 BA-29927 PI-26098 PN-29932 5014750 SC-29933 TM-29920 TM-29921 TM-29923 TM-29922 CC-34682 CC-35050 PE-29624 Description Dinrail, End Stop Digital Relay 2, Circuit Board Digital Relay 1, Circuit Board Din Rail Mounting Bracket, 160mm Long Connector, Flat Base M.D.
parts information QC-20 Bottom 8 6 7 6 4 3 2 5 1 Item 1 2 3 4 5 6 7 8 Part PN-29968 FI-29954 VA-29900 RE-29947 CD-29831 RE-29966 EL-29828 FU-29965 Description Compressor Louver Filter Dryer Valve, Pressure Regulator Compressor, 3/4 HP LO R404A Cord with Plug, 20Amp 125V 5-20P, 9' Long Condensate Evaporator Pan - includes Hold Down Bracket Element Condensate Pan, 115V 200W Evap. 000274 N Breaker, 1 Pole 20 Amp QUICKCHILLER PARTS • MN-29647 (REV. 0) • INSTALLATION/OPERATION/SERVICE MANUAL • 36.
parts information QC-20 Box view 1 2 3 4 5 6 7 8 20 9 10 21 18 20 19 18 Show with optional side racks 17 16 15 11 12 14 13 Item 1 2 3 4 5 6 7 8 9 10 11 12 Part CU-29964 BT-29918 FU-29926 BK-29919 BA-29927 FA-29945 PR-34299 5009220 SC-29835 HG-29959 DR-29957 HG-29834 *not shown Description Qty. Capacitor, 14MFD, 440VAC 1 Din Rail 1 Fuse.
parts information QC-20 coil view 1 17 16 2 15 3 4 14 13 5 6 12 11 9 10 Item 1 2 3 4 5 6 7 8 Part RE-29944 PR-34704 SN-33541 BK-24427 SN-34663 CD-29860 PN-29943 TE-35100 Description Coil, QuickChiller Probe Receptacle Assembly Cavity Sensor Mounting Block for Air Sensor Coil Sensor/, Defrost/Sensor Wire, 11" (279mm) Loop Drain Heater Evaporator Pan, without Element Copper Tee, 1/2" ID Qty.
parts information QC-20 Compressor view 1 2 3 4 5 4 6 7 9 Item 1 2 3 4 5 6 7 8 9 10* 11* Part FI-29954 VA-29900 RE-29947 VA-29863 IN-29952 BT-29951 RE-29948 BT-29950 PN-29949 MO-29955 FA-29956 8 Description Filter Dryer Solenoid Valve, Sporlan Pressure Regulator Compressor Solenoid Valve & 120V Coil Insulation Wrap Bracket, Back Compressor Hold Down Condensing Unit, 3/4 HP LT R404A 120V Bracket, Front Compressor Hold Down Housing Motor, 3/4 HP Compressor Fan Motor Fan Blade for Compressor Fan M
parts information QC-20 Control PaneL 1 Apply Weather Stripping to Front Top Edge of Panel 2 9 3 4 8 Item 1 2 3 4 5 6 7 8 9 10* 11* 7 6 5 5 Part SC-29933 CC-34682 PI-26098 PN-29962 5014750 TM-29920 TM-29923 TM-29922 TM-29921 CC-35050 PE-29624 Description Bolt, M5 Control Board Pipe, .
parts information QC2-40 compressor 3 4 2 1 2 5 6 7 Item 1 2 3 4 5 6 7 Part VA-29898 SE-29897 VA-29900 FI-29899 EL-29828 PN-29903 RE-29896 Description Valve, Liquid Line Solenoid Solenoid Valve & Coil, Danfoss, 120V Valve, Sporlan Crankcase Pressure Regulator Filter Drier Element Condensate Pan, 115V 200W Evap. 000274 N Evaporator Pan, without Element Condensing Unit, 1.5 HP 230V 1 Phase QUICKCHILLER PARTS • MN-29647 (REV. 0) • INSTALLATION/OPERATION/SERVICE MANUAL • 41. Qty.
parts information QC2-40 compressor Housing 1 1 6 5 4 2 3 Item 1 Part Description Qty. FU-29901 Breaker, 2 Pole 20 AMP, 60Hz 1 FU-29996 Breaker, 2 Pole 30 AMP, 50Hz 1 2 PE-29902 Compressor Louver 1 3 LG-29904 6" Leg, Standard (152mm) 4 SC-29824 Leg Bolt, 1/4-20 x 3.5" Shoulder Bolt Hex Head 16 4 PN-29903 Evaporator Pan, without Element 1 5 RE-29896 Condensing Unit, 1.
Q C 2 - 4 0 c o IL parts information 1 Suction Line 2 1 Hot Gas Defrost Line 3 Discharge Line 2 Item 1 2 3 4 Part RE-29905 VA-29906 CD-29860 SN-34663* Description Coil Assembly, 19x20 Valve, Expansion Wire, 11" (279mm) Loop Drain Heater Coil Sensor/Defrost Sensor *not shown QUICKCHILLER PARTS • MN-29647 (REV. 0) • INSTALLATION/OPERATION/SERVICE MANUAL • 43. Qty.
parts information Q C 2 - 4 0 D OOR , l e f t h a n d ( p r i o r t o j u n e 1 , 2 0 1 2 ) 1 7 4 6 2 5 4 3 Item 1 2 3 4 5 6 7 8 9* Part HG-29913 HD-26967 BT-29911 HG-29912 SC-29910 GS-29914 HL-29840 DR-29909 LT-3738 Description Upper Hinge, Bracket, Left-Hand Handle, Door Lower Bracket, Horizontal Pivot, Left-Hand Hinge Insert, Self Closing Screw, 10x2" THP Gasket, Door Food Probe Holder Door Assembly without Handle or Hinges Door Switch *not shown QUICKCHILLER PARTS • MN-29647 (REV.
Q C 2 - 4 0 D OOR ( a f t e r j u n e 1 , 2 0 1 2 ) parts information left-hand right-hand 4 1 1 2 4 2 1 3 3 1 Item 1 2 3 4 Part HG-29992 HL-29840 GS-29914 HD-26967 Description Hinge, Adjustable Food Probe Holder Gasket, Door Handle, Door Qty. 1 3 1 1 QUICKCHILLER PARTS • MN-29647 (REV. 0) • INSTALLATION/OPERATION/SERVICE MANUAL • 45.
parts information Q C 2 - 4 0 INTERIOR 1 2 3 4 6 5 4 Item 1 2 3 4 5 6 7* 8* Part PR-34299 PR-34298 PE-29916 SR-29915 PE-29917 SN-33541 SH-22584 LT-3738 Description Probe, Receptacle Probe, Quick Connect Panel, Fan Guard, Right Rack, Pan Support Panel, Fan Guard, Left Cavity Sensor Shelf, Stainless Steel Wire Door Switch *not shown QUICKCHILLER PARTS • MN-29647 (REV. 0) • INSTALLATION/OPERATION/SERVICE MANUAL • 46. Qty.
parts information QC2-40 Control Panel - Hinged left (prior to june 1, 2012) 1 12 3 2 5 4 6 7 13 14 17 20 18 15 19 11 16 19 10 9 8 Item 1 2 3 4 5 6 7 8 9 10 11 Part TM-29921 TM-29922 TM-29923 TM-29920 SC-29928 CC-34682 PI-26098 CC-29930 HG-29931 BT-29918 LT-26969 *not shown Description Terminal Block, Pluggable, 180 Deg, 7 Position Terminal Block, Pluggable, 180 Deg, 8 Position Terminal Block, Pluggable, 180 Deg, 10 Position Terminal Block, Pluggable, 90 Deg, 9 Position Bolt, 6-32x1/2,
parts information QC2-40 Control Panel - hinged left (After june 1, 2012) 60Hz 50Hz 17 1 1 2 2 17 3 3 16 16 4 5 5 6 6 7 7 7a 8 15 14 8 15 9 9 10 14 10 11 11 13 Item 1 2 3 4 5 6 7 7a 8 9 Part TM-29921 TM-29922 TM-29923 LT-26969 TM-29920 BK-29919 FU-29934 FU-29997 BA-29927 BT-29929 4 Description Terminal Block, Pluggable, 180 Deg, 7 Position Terminal Block, Pluggable, 180 Deg, 8 Position Terminal Block, Pluggable, 180 Deg, 10 Position Door Latch Terminal Block, Pluggable, 90 D
parts information QC2-40 Control Panel - hinged right (After june 1, 2012) 60Hz 50Hz 17 17 1 2 2 3 3 4 4 15 1 16 16 15 5 5 6 6 7 7 7a 8 8 9 14 13 9 14 10 10 13 11 11 12 Item 1 2 3 4 5 6 7 7a 8 9 Part SC-29928 TM-29921 TM-29922 TM-29923 TM-29920 BK-29919 FU-29934 FU-29997 BA-29927 BT-29929 Description Bolt, 6-32x1/2, Philip Truss Head Terminal Block, Pluggable, 180 Deg, 7 Position Terminal Block, Pluggable, 180 Deg, 8 Position Terminal Block, Pluggable, 180 Deg, 10 Position
parts information Q C 2 - 4 0 FAN 1 2 3 Item Part 1 FA-29853 RE-35856 2 FT-29908 3 FA-29907 Description Motor, Fan Evaporator, 60Hz Motor, Fan Evaporator, 50Hz Plastic Collar, 14-1/2" Round Blade, 14" Evaporator Fan QUICKCHILLER PARTS • MN-29647 (REV. 0) • INSTALLATION/OPERATION/SERVICE MANUAL • 50. Qty.
parts information QC2-100 compressor 8 7 6 5 1 2 3 2 Item 1 2 3 4 5 6 7 8 Part TE-29986 RE-35155 TE-35153 VA-29898 TE-35154 EL-35152 FI-29987 RE-29983 RE-35172 4 Description Tee, Copper, 3/8 x 3/8 x 3/8" ID Solenoid Valve & Coil, Danfoss, 120V Tee, Copper, 1/2 x 1/2 x 3/8" ID Valve, Liquid Line Solenoid Tee, Copper, 1-1/8 x 1-1/8 x 5/8" OD Elbow, Copper 1/4" Street Filter Drier Condensing Unit, 3HP 208/230V 1 Phase Condensing Unit, 3HP 208/230V 3 Phase QUICKCHILLER PARTS • MN-29647 (REV.
parts information Q C 2 - 1 0 0 c o IL 5 1 2 3 4 Item 1 2 3 4 5 6* Part RE-29905 VA-29906 TE-35153 FA-29945 TE-29985 SN-34663 Description Coil Assembly, 19x20 Valve, Expansion Tee, Copper, 1/2 x 1/2 x 3/8" ID Fan, Axial Evaporator Coil Tee, Copper, 1/2" x 1/2" x 1/4" ID Coil Sensor, Defrost/Sensor *not shown QUICKCHILLER PARTS • MN-29647 (REV. 0) • INSTALLATION/OPERATION/SERVICE MANUAL • 52. Qty.
parts information Q C 2 - 1 0 0 D OOR 5 6 4 3 1 2 Item 1 2 3 4 5 6 7* Part HD-26967 GS-29994 GS-29993 HG-29992 SC-29991 HL-29840 LT-3738 DR-35858 DR-35857 Description Handle, Door Gasket, Compression Gasket, Door Hinge, Adjustable Screw, Pan Head, 8-32 x 1/2" Long Food Probe Holder Door Switch Door Assembly, LH, without Handle or Hinges Door Assembly, RH, without Handle or Hinges *not shown QUICKCHILLER PARTS • MN-29647 (REV. 0) • INSTALLATION/OPERATION/SERVICE MANUAL • 53. Qty.
parts information Q C 2 - 1 0 0 INTERIOR , l e f t - h a n d v i e w 1 9 10 11 12 13 2 3 6 8 7 Item Part 1 RE-29983 RE-35172 2 PN-29842 3 PN-29999 4 DR-29990 5 HG-29992 6 GS-29994 7 contact factory 8 5014889 *not shown 4 5 Description Condensing Unit, 3HP 208/230V 1 Phase Condensing Unit, 3HP 208/230V 3 Phase Louver Panel Panel, Control Panel Assembly, LH Door Assembly, LH without Hinges and Handle Hinge, Adjustable Gasket, Compression Trolley Guides Legs Qty.
parts information Q C 2 - 1 0 0 INTERIOR , r i g h t - h a n d v i e w 1 8 9 10 11 12 2 6 7 Item Part 1 RE-29983 RE-35172 2 PN-29842 3 DR-35857 4 PN-35935 5 GS-29994 6 contact factory 7 5014889 8 BK-29919 *not shown Description Condensing Unit, 3HP 208/230V 1 Phase Condensing Unit, 3HP 208/230V 3 Phase Louver Panel Door Assembly, RH without Hinges and Handle Control Panel Assembly Gasket, Compression Trolley Guides Legs Block, Fuse Holder, 20A 300VAC 5 Qty.
parts information QC2-100 Control Panel, unit hinged left 14 15 16 17 18 19 20 1 13 12 11 10 2 9 8 3 7 4 6 5 Item 1 2 3 4 5 6 7 8 9 10 11 12 Part CC-34682 5014750 TI-35860 PN-29999 SC-29991 LT-26969 CU-29964 BK-35859 BA-34009 BA-34010 BT-29929 BT-29918 *not shown Description Control Board HACCP Data Logger, USB Port, option Strap, Transformer Tie Down Control Panel Assembly Bolt, Phillips Truss, 8-32 Door Latch, Left-Hand Capacitor, 14MFD, 440VAC Terminal Block, Twin Cond.
parts information QC2-100 Control Panel, unit hinged right 16 17 18 19 1 15 2 14 13 12 3 11 10 4 9 5 8 6 7 Item 1 2 3 4 5 6 7 8 9 10 11 12 Part CC-34682 TI-35860 5014750 BT-29929 LT-26968 SC-29991 PN-29999 CU-29964 BK-35859 BA-34009 BA-34010 BT-29918 *not shown Description Control Board Strap, Transformer Tie Down HACCP Data Logger, USB Port, option Dinrail, End Stop Door Latch, Right-Hand Bolt, Phillips Truss, 8-32 Control Panel Assembly, RH Capacitor, 14MFD, 440VAC Terminal Block, Twin Cond.
TRANSPORTATION DAMAGE and CLAIMS 1. 2. 3. 4. 5. 6. 7. 8. All Alto-Shaam equipment is sold F.O.B. shipping point, and when accepted by the carrier, such shipments become the property of the consignee. Should damage occur in shipment, it is a matter between the carrier and the consignee. In such cases, the carrier is assumed to be responsible for the safe delivery of the merchandise, unless negligence can be established on the part of the shipper.