Specifications
An electrical wiring diagram is located behind the
control panel on the left side of the oven. This
appliance must be branch circuit protected with proper
ampacities, in accordance with the wiring diagram
located in the electrical compartment of the oven.
Wire size for the main incoming power to the unit
must match the minimum size listed in the
specifications applicable to the specific oven model.
For supply connections, locate the wire size posted on
the label located on the electrical control box cover,
behind the service panel.
Before operating the oven, check all cable connections
in the electrical connection area for tightness since
connections can loosen during transport.
NOTE: After both water and electrical connections
have been completed, operate the oven in
any cooking mode for a period of 15 minutes
and recheck the main power connections at
the terminal block to make certain they
remain tight.
G A S C O M B I T H ER M — I N S TA L L AT I O N M A NU A L #MN-28898
PG. 14
®
COMBITHERM
ELECTRICAL & INSTALLATION REQUIREMENTS
MODEL VOLTAGE PHASE CYCLE/HZ AMPS KW CIRCUIT AWG
6•10esG 110-120 1 50/60 5.7 .68 20 A 2 W
IRE
PLUS GROUND
6•10esG/SK 110-120 1 50/60 9.5 1.14 20 A AWG 12
7•14esG 110-120 1 50/60 5.7 .68 20 A 2
WIRE
PLUS GROUND
7•14esG/SK 110-120 1 50/60 9.5 1.14 20 A AWG 12
10•10esG 110-120 1 50/60 5.7 .68 20 A 2
WIRE
PLUS GROUND
10•10esG/SK 110-120 1 50/60 9.5 1.14 20 A AWG 12
10•20esG 110-120 1 50/60 7.8 .936 20 A 2
WIRE
PLUS GROUND
AWG 12
12•18esG 110-120 1 50/60 7.8 .936 20 A 2
WIRE
P
LUS GROUND
AWG 12
20•20esG 110-120 1 50/60 22.0 2.64 30 A 2
WIRE
PLUS GROUND
AWG 10
OTHER VOLTAGES AVAILABLE: Range 200 — 415V, 1 or 3 ph, 50 or 60 Hz
380-415V:
To prevent an electrical shock hazard
between the appliance and other appliances
or metal parts in close vicinity, an
equalization-bonding stud is provided.
An equalization bonding lead must be
connected to this stud and the other
appliances / metal parts to provide
sufficient protection against potential
difference. The terminal is marked with
the following symbol.
D A N G E R
ELECTRICAL GROUNDING
INSTRUCTIONS:
This appliance is equipped with a
three-pronged (grounding) plug for
your protection against shock hazard
and should be plugged directly into a
properly grounded three-prong
receptacle. Do not cut or remove the
grounding prong from this plug.
D A N G E R
AVERTISSEMENT: Directives
pour la prise de courant électrique Cet
appareil est muni d'une fiche à trios
branches (prise de Courant) afin de
vous proéger des chocs et doit être
branché Directemet dans un receptacle
adequate de prise do courant À trios
branches. II ne faut pas couper ou
enlever une banche De cette fiche.
D A N G E R
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in according with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.