Mobile Refrigerated Cart Double Compartment Model: 1000-MR2 • Installation • Operation • Maintenance W164 N9221 Water Street • P.O. Box 450 • Menomonee Falls, Wisconsin 53052-0450 USA PHONE: 262.251.3800 • 800.558.8744 USA / CANADA FAX: 262.251.7067 • 800.329.8744 u . s . a . OnLY www.alto-shaam.com printed in u.s.a.
ITEM NO. _______________________ 1000-MR2 mobile refrigerated cart l The Alto-Shaam Mobile refrigerated Cart is not just a refrigerator on wheels, but a well-designed and efficient system for storing and transferring refrigerated food products. Adjustable shelves allow for the storage of plated items, pans or other items. l l Full perimeter stainless steel bumper, transport handles, heavy duty casters along with the cart’s reduced height provide easy mobility.
1000-MR2 mobile refrigerated cart 27" (685mm) 57-11/16" (1465mm) 27" (685mm) 26-7/8" (682mm) 29-1/4" (742mm) dim ens io ns : H x W x D exterior : 68-1/2" x 67-1/2" x 29-1/4" (1740mm x 1715mm x 742mm) interior per compartment : 21-1/4" x 27-1/4" x 55-1/2" (540mm x 692mm x 1410mm) E LECTRICA L 67-1/2" (1715mm) with bumper voltage phase cycle/hz amps kW cord 220-240 1 50 5.5 1.
ALTO-SH HAAM MOBILE M E REFR RIGERA ATED C CARTS 1.0 IN NTRODUCTIO ON This tec chnical manua al provides in nformation on n the insttallation, ope eration, maintenance and d inspectio on of this unit. A com mplete parts s breakdo own is provide ed. 1.1 EQU UIPMENT DES SCRIPTION The unit consists of th he following: Storage compartment: The ins sulated food d storage compartmen nt is clear storage s area. d in this area are a the adjus stable shelves s Included and coolling coil.
PROC CEDUR RES CONTROL L AND INDICA ATION STAR RT-UP PROCE EDURE NAME TYPE E FUNCTION OPER RATION RESULT TS Thermostat Contac ct Points Cyc cles the Activa ate system by The comp pressor should refrigeration electri cal service cord immediate ely come on-line system (automatic) into el ectrical supply and the evvaporator fan acttivate. source e Turn power Power Control Contac ct Points Terminates power switch h to the "ON" Switch(ON/O OFF) to th he unit positio on.
OPERATIO ON / CLE EANING 4.0 OPE ERATING PRO OCEDURE The purp pose of this mobile refrig gerator is to o maintain cold food ds at prop per serving g ures. The unit should the t intended d temperatu purpose only. o a) Adjjust the po osition of the shelves s accommo odate required d storage nee eds. h the power to o the "ON" position b) Switch hill the cabine et to the full, factory f presett c) Pre-ch temperatu ure of 36°F ±3 3°F (2.C) d) Load the refrigerattor with chilled foods only.
SCH HEDULED MAINT TENANC CE 6.0 MAIN NTENANCE 6.3 Remembe er to de-enerrgize the unit by switching g the toggle e switch locatted on the control panel to o the "OFF"" position. Dis sconnect the unit from the e power sou urce. ore making an ny adjustmentt to the therm mostat, Befo checck the door g gasket for prroper seal. P Proper adjusstment can b be tested by pulling a dolllar bill throu ugh the gassket seal and d feeling a slight resisstance.
SCH HEDULED MAINT TENANC CE 6.6 DOOR HANDLE REPLACEME R ENT NOT TE: GE REPLACE EMENT 6.8 DOOR HING It may be necessarry to remove e y in order to o the handle assembly ough a doorr get the cabinet thro opening. NOTE: T This procedurre will require two p people. One person to ho old the d door while tthe other rem moves th he attachmen nt screws. R the th hree side mou unting screws s 1. Remove in n latch. 2. Remove R two screws in strik ke. 3. Replace R in rev verse order. 1 1.
CO ORRECTIVE MAIN NTENANCE TROUBLE SH HOOTING GUIDE E SYMPTOMS S Un nit does not cool. Unitt does not ope erate. Unit runs continuo ously. POSSIBLE FAILUR RE Low refrigerant. Control failure. orrect voltage.. Inco Bad connection a at supply d. cord Faile ed compresso or. Low on Refrigera ant. Control failure. w or Resttricted air flow dirty y condenser ccoil. Bad condenser fa an or. moto Com mpressor failu re. Inefffective door sseal.
CO ORRECTIVE MAIN NTENANCE TROUBLE SH HOOTING GUIDE E 1000-MR2 (50HZ) OPERATION MANUAL #02/13 7/14
1000-MR2 (50HZ) OPERATION MANUAL #02/13 8/14
MR2 SERVICE PARTS DESCRIPTION Rubber Wheel 5" Roller Brake Rubber Wheel 5" Fixed Comp. 220V 50Hz Cond. Coil Cond. Fan Motor (Complete set) Drain - Hot Gas Door Hinge Door Latch Handle PVC Box QTY PART NUMBER 3 191115 3 191154 1 1 1119450Z 2541011 1 I105009 1 4 2 1 048102 1811 I10835 073840 1000-MR2 (50HZ) OPERATION MANUAL #02/13 DESCRIPTION QTY PART NUMBER Filter Dryer Accumulator Access valve Heater Door Gasket Assy PVC.
1000-MR2 (50HZ) OPERATION MANUAL #02/13 10/14
1000-MR2 (50HZ) OPERATION MANUAL #02/13 11/14
PARTS IDENTIFICATION Suction Line Discharge Line Electric Box COMPRESSOR FOR MR2 ELECTRICAL DIAGRAM 1000-MR2 (50HZ) OPERATION MANUAL #02/13 12/14
1000-MR2 (50HZ) OPERATION MANUAL #02/13 13/14
transPortatIon DaMaGe and claIMs 1. 2. 3. 4. 5. 6. 7. 8. All Alto-Shaam equipment is sold F.O.B. shipping point, and when accepted by the carrier, such shipments become the property of the consignee. Should damage occur in shipment, it is a matter between the carrier and the consignee. In such cases, the carrier is assumed to be responsible for the safe delivery of the merchandise, unless negligence can be established on the part of the shipper.