Specifications


ELECTRONIC CONTROL ACCURACY
The electronic control is a precise instrument and is
designed to offer trouble-free service. If you suspect
the temperature inside the warming cabinet does
not match the temperature indicated on the digital
display, after stabilizing, follow the instructions
listed below.
1. Check to make certain the unit voltage matches
the power source. A power source less than
that required to operate the unit will result in
inaccurate temperatures.
2. Verify the temperature inside the holding
compartment with a quality thermal indicator.
A. With the exception of the wire shelves,
completely empty the holding compartment.
B. Make certain the holding cabinet sensor,
located inside the holding compartment at
the left side of the unit, is completely clean.
C. Suspend the thermal indicator in the center
of the holding compartment.
D. Allow the temperature set on the electronic
thermostat to stabilize for a minimum of one
hour before comparing the digital display
with the reading on the thermal indicator.
DO NOT OPEN THE CABINET
DOOR(S) DURING THE TEMPERATURE
STABILIZATION PERIOD.
If the reading on the thermal indicator does not
match the digital display, there may be a problem
with the air sensor. See troubleshooting guide in
this manual, or call the factory service department
for advice.
SPECIAL FEATURES
HEAT RECOVERY
The patented SureTemp™ heat recovery system in
this unit will immediately compensate for any loss of
heat when the door is opened. in order to maintain a
more consistent cavity temperature, the control will
automatically apply heat to the unit’s interior while
the door is open and for a short time after the door is
closed. If the door remains open for more than three
minutes, the solid state electronic control will sound
three rapid beeps every ten seconds until the door
is closed.
DANGER
DISCONNECT UNIT FROM

CLEANING OR SERVICING.
SERVICE
CAUTION
THIS SECTION IS PROVIDED FOR THE ASSISTANCE
OF QUALIFIED SERVICE TECHNICIANS ONLY AND
IS NOT INTENDED FOR USE BY UNTRAINED OR
UNAUTHORIZED SERVICE PERSONNEL.
This section is provided for the assistance of qualified technicians only and is not intended for use by
untrained or unauthorized service personnel. If your Alto-Shaam
®
unit is not operating properly, check the
following before calling your Authorized Alto-Shaam
®
Service Agent:
* Check main power circuit breaker to the unit and circuit breaker on the back of the unit is turned on, if applicable.
Do not attempt to repair or service the holding cabinet beyond this point. ContactAlto-Shaam
®
forthe
nearestauthorizedserviceagent.Repairsmadebyanyotherserviceagentswithoutpriorauthorization
byAlto-Shaam®willvoidthewarrantyontheunit.
NOTE
If the appliance has been unplugged for an
extended period of time, the Real Time Clock may
require recharging. Turn main breaker to the unit
off for 10 seconds and then restore power.
For more information, see Error Code E-60 in
the Troubleshooting section of this manual.
DANGER
LOCK-OUT OR POST

SERVICE WORK HAS

