After the water heater has been running for more than 15 minutes, it will
be running at full capacity. If you want to make the heat pump run more
efficiently the water flow should be adjusted by checking the pressure
meter display.
If the meter index is in the green area, the water heater is running in the
most efficient way and you do not need to adjust anything.
In the event that the pressure reading is in the red area
‘A’ (dia.2) it
means there is insufficient water flow. Prior to any adjustments make
sure your filter is clean by using the ‘backwashing and rinse procedure
(refer to your pool hand book for guidance). Check there are no
obstructions in the suction lines i.e. Main Drain or Skimmer(s). If you
are unable to increase the flow rate, please contact your pool dealer as
you may need to increase the size of the filtration pump.
It is not critical if the the pressure reading is not in the green area.
If the reading is marginally in the red area either side do not be
overly concerned, the heater will still function normally.
diagram 1
diagram 3
diagram 2
In the event that the pressure reading is in the red area
‘B’ (dia.3) it
means the water flow is too high. You may need to install a bypass to
decrease the water flow until pressure meter enters the green area.
Please contact you dealer for advice.
FLOW METER