Data Sheet

ACM8CBE
Multi-Output Access Power Controllers
Rev. DSACM8CBE_06192014
ACM8CBE converts one (1) 12 to 24 volt AC or DC input into eight (8)
independently controlled PTC protected outputs. These power outputs can be
converted to dry form “C” contacts. Outputs are activated by an open collector
sink or normally open (NO) dry trigger input from an Access Control System,
Card Reader, Keypad, Push Button, PIR, etc. The ACM8CBE will route power
to a variety of access control hardware devices including Mag Locks, Electric
Strikes, Magnetic Door Holders, etc. Outputs will operate in both Fail-Safe
and/or Fail-Secure modes.
This unit is designed to be powered by one common power source which will
provide power for both the board operation and locking devices, or two (2)
totally independent power sources, one (1) providing power for board opera-
tion and the other for lock / accessory power. The FACP Interface enables
Emergency Egress, Alarm Monitoring, or may be used to trigger other auxiliary
devices. The fire alarm disconnect feature is individually selectable for any or
all of the eight (8) outputs.
Overview
Specifications
Agency Approvals
UL Listed for Access Control Systems
Units (UL 294).
CUL Listed - CSA Standard C22.2
No. 205-M1983 Signal Equipment.
Altronix Corp.
140 58th St. Brooklyn, NY
CSFM - California State Fire
Marshal Approved.
MEA - NYC Department of
Buildings Approved.
ACM8CBE
Input:
• 12to24voltACorDCoperation
(setting not required), 0.6 amp @ 12volt,
0.3 amp @ 24 volt current consumption with all
relays energized.
• Powersupplyinputoptions:
a) One (1) common power input
(board and lock power).
b) Two (2) isolated power inputs (one (1) for
board power and one (1) for lock/accessory power).
• Eight(8)AccessControlSystemtriggerinputs:
a) Eight (8) normally open (NO) inputs.
b) Eight (8) open collector sink inputs.
c) Any combination of the above.
Output:
• Eight(8)independentlycontrolledoutputs:
a) Eight (8) Fail-Safe and/or Fail-Secure
power outputs.
b) Eight (8) dry form “C” 5 amp rated relay outputs
c) Any combination of the above
• Eight(8)auxiliarypoweroutputs(unswitched).
• Outputratings:
- PTCs are rated 2.5 amp each.
• Mainfuseisratedat10amp.
Note:Totaloutputcurrentisdeterminedbythepower
supply, not to exceed a maximum of 10 amp total.
Features:
• FireAlarmdisconnect(latchingornon-latching)is
individually selectable for any or all of the
eight (8) outputs.
FireAlarmdisconnectinputoptions:
a) Normally open (NO) or normally closed (NC)
dry contact input.
b) Polarity reversal input from FACP
signaling circuit.
• FACPoutputrelay(form“C”contactrated@1amp
28VDC not evaluated by UL).
• Removableterminalblocksfacilitateease
of installation.
Visual Indicators:
• RedLEDsindicateoutputsaretriggered
(relays energized).
• GreenLEDindicatesFACPdisconnectistriggered.
Electrical:
• Operatingtemperature:0ºCto49ºCambient.
• BTU/Hr.:
- 12VDCor12VAC:3.68BTU/Hr.
- 24VDCor24VAC:3.68BTU/Hr.
Mechanical:
• EnclosureDimensions(HxWxDapprox.):
15.5” x 12” x 4.5” (393.7mm x 304.8mm x 114.3mm)
• Productweight(approx.):6.7lbs.(3.04kg).
• Shippingweight(approx.):7.6lbs.(3.45kg).

Summary of content (2 pages)