Data Sheet

Input:
Input 115VAC, 60Hz, 3.5 amp.
Input fuse rated @ 3.5 amp/250V.
Fire Alarm Panel or Access Control System trigger
inputs. N.O. or N.C. supervised trigger input and
polarity reversal trigger input.
Output:
12VDC or 24VDC selectable outputs.
6 amp supply current.
Five (5) PTC protected Class 2 Rated power-limited
outputs, rated @ 2 amp.
Output relay energizes when unit is triggered
(form “C” contact rated 1 amp @ 28VDC).
Filtered and electronically regulated output.
Short circuit and thermal overload protection.
Battery Backup:
Built-in charger for sealed lead acid or
gel type batteries.
Automatic switch over to stand-by battery
when AC fails.
Maximum charge current 0.7 amp.
Supervision:
AC fail supervision (form “C” contacts).
- Notification trigger is selectable for
30 seconds (factory set) or 6 hours.
Supervision (cont’d):
Low battery supervision (form “C” contacts).
Battery presence supervision (form “C” contacts).
Power fail supervision relay (form “C” contacts).
Visual Indicators:
AC input and DC output LED indicators
(power supply board).
Red LEDs indicate condition of power outputs
(multi-output board).
Power and input trigger LEDs (multi-output board).
Electrical:
Operating temperature: 0º C to 49º C ambient.
• BTU/Hr.:
- 12VDC: 36.85 BTU/Hr.
- 24VDC: 73.7 BTU/Hr.
System AC input VA requirement: 402.5VA.
Mechanical:
Enclosure Dimensions (H x W x D approx.):
13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.55mm)
- Accommodates up to two (2) 12VDC/7AH batteries.
Product weight (approx.): 7.9 lbs. (3.58 kg).
Shipping weight (approx.): 8.9 lbs. (4.04 kg).
Specifications
AL600ULM
Multi-Output Power Supply/Charger
Rev. DSAL600ULM_05212015
AL600ULM multi-output access control power supply/charger is specifically
designed for use with access control systems and accessories. This unit con-
verts a 115VAC, 60Hz input into five (5) individually protected Class 2 Rated
power-limited 12VDC or 24VDC outputs. Each output will route power to a va-
riety of access control hardware devices including Mag Locks, Electric Strikes,
Magnetic Door Holders, etc. These outputs will operate in both Fail-Safe and
Fail-Secure modes. Controlled trigger input is achieved through normally open
(N.O.) or normally closed (N.C.) supervised input or the polarity reversal from
an FACP (Fire Alarm Control Panel). A form “C” dry output relay enables
HVAC Shutdown, Elevator Recall or it may be used to trigger auxiliary devices.
Overview
Agency Approvals
Altronix Corp.
140 58th St. Brooklyn, NY
CSFM - California State Fire
Marshal Approved.
MEA - NYC Department of
Buildings Approved.
UL 294 UL Listed for Access Control
System Units.
UL 1481 UL Listed Standard for Safety for
Fire Protective Signaling Systems.
CUL Listed - CSA Standard C22.2
No.205-M1983, Signal Equipment.
AL600ULM