Installation Guide

- 2 - eBridge4SK
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Wiring
should be UL Listed and/or Recognized wire suitable for the application.
eBridge100SPR and eBridge4SPT is not intended to be connected to outside plant leads and should be installed indoors within the protected premises. The
eBridge100SPR and eBridge4SPT is intended for indoor use only.
1. eBridge100SPR installation:
a. Secure unit to desired mounting surface with a proper fastening device utilizing the unit’s mounting hole.
Unit should be mounted in proximity to Ethernet switch/network, NVR or video server.
b. Connect 56VDC UL Listed Class 2 or limited power source to terminals marked [Power --- Input +] (observe proper polarity) (Fig. 1, pg. 3).
Use 22AWG-16AWG wire for this connection.
Caution: 56VDC will be present on coax. The other end of the coax should only be connected to the eBridge4SPT.
c. Connect structured cable from Ethernet switch/NVR (network video server) to RJ45 jack marked [10/100 BaseT] (Fig. 1, pg. 3).
d. Connect Coax cable to BNC connector marked [Coax] (Fig. 1, pg. 3).
2. eBridge4SPT installation:
a. Affix rubber pads to eBridge4SPT for shelf installation (Fig. 9, pg. 12).
b. Connect Coax cable from eBridge100SPR to BNC connector marked [Coax] located on the back of the unit (Fig. 1, pg. 3).
c. Connect structured cable from PoE/PoE+ cameras/devices to RJ45 jacks marked [1-4] (Fig. 1, pg. 3).
Note: The eBridge is designed to accommodate Megapixel, HD720, HD1080 and VGA (SD) cameras. It is important to note that some high resolution and high
frame rate cameras may demand faster headend processing ability, such as a PC graphics card to present a quality image. If the headend processing equipment
is insufficient in speed, the image may show pixelation and latency. It is advisable to pretest system if unsure. Alternatively, frame rate and resolution may be
reduced to accommodate system equipment.
Technical Specifications:
Parameter Description
Connections BNC for Coax link. RJ45 for Ethernet link.
Input power requirements
eBridge100SPR - 51-56VDC/60W @ max. power.
eBridge4SPT - powered by eBridge100SPR.
Indicators
Blue: Coax Link.
Yellow (RJ45 connector): On - Link, Off - No Link, Blinking - Activity.
Green (RJ45 connector): On - 100Base-TX, Off - 10Base-T.
Environmental Conditions
Operating Ambient Temperature (UL60950-1):
eBridge100SPR: -40ºC to 60ºC (-40ºF to 140ºF).
eBridge4SPT: 60W: -40ºC to 75ºC (-40ºF to 167ºF).
Relative humidity: 85%, +/ --- 5%
Storage Temperature: --40ºC to 75ºC (-40ºF to 167ºF).
Operating Altitude: --- 1000 to 6,561.679 ft. (--- 304.8 to 2000m).
Regulatory Compliance UL/CUL Listed for Information Technology Equipment (UL 60950-1). CE approved.
Weights (approx.)
eBridge100SPR - Product: 5.1 oz. (0.144 kg.), Shipping: 7.76 oz. (0.22 kg.)
eBridge4SPT - Product: 2.9 lbs. (1.32 kg), Shipping: 3.9 lbs. (1.77 kg)