Installation Guide

eBridge4SK - 3 -
Typical Application:
Fig. 1
Maximum Length of Coax Type vs. Camera Power/PoE Class:
Camera Power/
PoE Class
RG59/U
(23AWG)
RG59/U
(22AWG)
RG59/U
(20AWG)
RG59/U
(18AWG)
RG6/U
(18AWG)
Max. Length (meters)
13W/0 or 13W/3 260.64m 335.28m 500m 500m 500m
25W 118.9m 150.6m 239.3m+ 365.8m+ 365.8m+
60W 50.3m+ 63.4m+ 100.6m+ 160m+ 160m+
Internet Browser Setup
Factory Default settings
IP Address: 192.168.168.168
User Name: admin
Password: admin
1. Set the static IP address for the laptop to be used for programming to the same network IP address as the eBridge4SPT, i.e. 192.168.168.200
(the default address of the eBridge4SPT is 192.168.168.168).
2. Connect one end of the network cable to the network jack on the eBridge100SPR and the other to the network connection of the laptop.
Coax up to 300m
Ethernet Switch
NVR Network
Video Server
(Head End
Equipment)
eBridge4SPT (Front View)
eBridge100SPR
CAT-5e
up to 100m
CAT-5e
up to
100m
CAT-5e
up to
100m
PoE
Output
10/100
Base-T
PoE/PoE+
Cameras
PoE/PoE+
Cameras
56VDC
Input