Installation Guide

Entrada2DMK - 3 -
Entrada2DMT (Fig. 1, pg. 2):
Factory Settings: FACP Disconnect is enabled and Lock power outputs are set for 12VDC. If these settings
meet your requirement, skip to Step 5.
1. Remove the four (4) screws from the Entrada2DMT cover.
2. For 24VDC lock outputs slide dip switch marked [SW1] to OFF (1) position,
for 12VDC lock outputs slide dip switch marked [SW1] to ON position (Fig. 3a, pg. 3).
3. To disable FACP Disconnect for either or both lock outputs slide the corresponding dip switches marked [S2]
to the ON position, to enable FACP Disconnect for either or both lock outputs slide the corresponding
dip switches marked [SW2 (1), SW2 (2)] to the OFF position (Fig. 3a, pg. 3).
4. Replace cover and secure it with four (4) screws.
5. Mount Entrada2DMT Transmitter in the desired location utilizing the unit’s mounting hole. Use a #6 fastener with
the proper wall anchor (ie. Ribbed Plastic, Drywall Anchor) when securing Entrada2DMR to the wall.
Note: Anchoring fasteners should accommodate a minimum of 3 lbs.
Unit should be located in proximity to the Locking Devices.
6. Connect structured cable from Listed Door Controller to the RJ45 jack marked [Network Door Controller].
7. Connect locking devices to the terminals marked [Lock Power Outputs + 1 -- , + 2 -- ], carefully observing polarity.
Note: All interconnecting devices must be UL Listed and low-voltage Class 2 power-limited.
8. Connect wet trigger output(s) from Listed Door Controller to the terminals marked [Wet Trigger Input + 1 -- ,
+ 2 -- ], carefully observing polarity.
Note: To ensure proper operation the Listed Door Controller must be programmed to apply power to the
Entrada2DMT terminals marked [Wet Trigger Input] to release Fail-Safe devices (Mag Locks) or programmed
to remove power from the Entrada2DMT to release Fail-Secure devices (Strikes).
9. Connect structured cable from Entrada2DMR to RJ45 jack marked [Entrada2DMR Receiver].
Note: System should be tested at least once a year.
Technical Specifications:
Parameter Description
Input power
requirements
For UL 60950-1 applications, use a UL Listed Endspan/Midspan LPS limited power source.
For UL 294 applications, use a UL 294 Listed PoE Midspan or Endspan (IEEE 802.3af/at).
Indicators
Entrada2DMR:
Midspan or Endspan RJ45 connector: Yellow - PoE UP.
Entrada2DMT Transmitter RJ45 connector: Green - Remote Aux. OFF.
Entrada2DMT:
Listed Door Controller RJ45 connector: Green - Output 2 ON, Yellow - Output 1 ON.
Entrada2DMR Receiver RJ45 connector: Green - PoE Output ON, Yellow - PoE Input ON.
Environmental
Conditions
Operating Ambient Temperature:
Entrada2DMR:
32ºF to 122ºF (0ºC to 50ºC).
Entrada2DMT:
For 16W @ 12VDC or 24VDC output--- 4ºF to 122ºF (--- 20ºC to 50ºC).
For 14W @ 12VDC or 24VDC output--- 4ºF to 131ºF (--- 20ºC to 55ºC).
Total power DC output plus PoE output not to exceed 30W.
Relative humidity: 85%, +/ --- 5%
Storage Temperature: --- 4ºF to 167ºF (-20ºC to 75ºC).
Operating Altitude: --- 1000 to 6,561.679 ft. (--- 304.8 to 2000m).
Regulatory
Compliance
UL/CUL Listed for: Information Technology Equipment (UL 60950-1).
UL Listed for: Access Control System Units (UL 294).
Compliance with IEEE 802.3 (at or af) specifications were not verified as part of UL294/B.
CSFM - California State Fire Marshal Approved.
CE - European Conformity.
Weights
(approx.)
Entrada2DMR: Product: 0.25 lbs. (0.11kg), Shipping: 0.42 lbs. (0.19kg)