Installation Instructions
- 2 - NetWay1DWP/NetWay1DWPH/NetWay1DWPM/NetWay1DWPMH
8. To facilitate wire entry utilize weather tight NEMA rated connectors (supplied), bushings and cable.
9. Connect structured cable from UL Listed ethernet switch or video server to RJ45 jack marked [IN] on
NetWay1DWP/NetWay1DWPH/NetWay1DWPM/NetWay1DWPMH (Fig. 1, pg. 2).
10. Connect structured cable from camera/device to RJ45 jack marked [OUT] on NetWay1DWP/NetWay1DWPH/
NetWay1DWPM/NetWay1DWPMH (Fig. 1, pg. 2).
11. Switch circuit breaker to the ON position.
Technical Specifications:
Parameter Description
Number of Ports One (1) Hi-PoE (60W) or IEEE 802.3at (30W) and IEEE 802.3af (15W) compliant.
Input power requirements 115VAC, 60Hz, 1.2 amp or 230VAC, 50/60Hz, 0.75 amp.
Environmental Conditions
Operating Ambient Temperature: 30W = 158ºF (70ºC). 60W = 131ºF (55ºC).
Relative humidity: 20 to 85%, non-condensing.
Storage Temperature: --- 22ºF to 185ºF (--- 30ºC to +85ºC) Storage.
Operating Altitude: --- 1000 to 6,561.679 ft. (--- 304.8 to 2000m).
Regulatory Compliance
UL/CUL Listed for Information Technology Equipment (UL 60950-1)
Information Technology Equipment to be installed Outdoors (UL 60950-22). CE approved.
Weights (approx.) Product: 3.7 lbs. (1.68 kg), Shipping: 5 lbs. (2.27 kg)
Fig. 2 - Bottom of enclosure
Typical Application:
Fig. 3
Ethernet Switch
Video
Monitor
NVR/Network Server
OUT IN
CAT-5 or
Higher
100m
CAT-5 or
Higher
100m
Camera/
Device
115VAC/230VAC
Input
LGN
Line Neutral
Ground
0.875”
22.22mm
4.25”
107.95mm
2.4375”
61.91mm
1.125”
28.575mm
1.125”
28.575mm
1.25”
31.75mm
Suggested area
for Inlets