surveillance
®
Stand-by time (for all Reserv models):
video surveillance ups
Batteries
4 amp (100VA) max. Load at
24VAC and/or 12VDC
Two (2) 12VDC/7AH 45 minutes
Two (2) 12VDC/12AH 90 minutes
ReServ1
• Sixteen (16) power outputs:
- Twelve (12) true sine wave regulated 24VAC outputs @ 4 amp
total supply current.
- Four (4) regulated 12VDC outputs @ 2 amp total supply current.
ReServ1WP
• ReServ1 with NEMA4 / IP66 Rated outdoor enclosure.
Enclosure dimensions: 17.5"H x 12"W x 6.625"D
*Stand-by times are approximate.
RESERV1
Features:
• UL Listed in the U.S. and Canada for
Information Technology Equipment.
• PTC protected power-limited outputs.
• Individual power LED indicators.
• Low voltage input and Shutdown LED indicators.
• AC fail and low battery supervision.
• Audible alarm provides notification of UPS trouble conditions.
• Built-in charger for sealed lead acid or gel type batteries.
• Enclosure accommodates two (2) 12VDC/7AH batteries
(order separately).
• Includes cam lock and battery leads.
Enclosure dimensions: 13.5"H x 13"W x 3.25"D
(order batteries separately)
112