K.M. Thomas

35
altronix.com
access
®
ACM Series Feature:
12 or 24 AC or DC operation (setting not required).
Power supply input options:
a) One (1) common power input (board and lock power).
b) Two (2) isolated power inputs (one (1) for board power
and one (1) for lock/hardware power).
Eight (8) Access Control System trigger inputs.
Input options:
a) Eight (8) normally open [NO] inputs.
b) Eight (8) open collector inputs.
c) Any combination of the above.
Eight (8) independently controlled fuse protected outputs.
Output options
(AL400ULACM, AL600ULACM, AL1012ULACM and AL1024ULACM):
a) Eight (8) Fail-Safe and/or Fail-Secure power outputs.
b) Eight (8) form “C” 5 amp rated relay outputs
c) Any combination of the above.
Output options (AL400ULACMCB, AL600ULACMCB,
AL1012ULACMCB and AL1024ULACMCB):
a) Eight (8) Fail-Safe and/or Fail-Secure power outputs.
Eight (8) auxiliary power outputs (unswitched).
ACM8 main fuse is rated @ 10 amp.
Red LEDs indicate outputs are triggered (relays energized).
Fire Alarm disconnect (latching or non-latching) is individually selectable
for any or all of the eight (8) outputs.
Fire Alarm disconnect input options:
a) Normally open [NO] or normally closed [NC] dry contact input.
b) Polarity reversal input from FACP signaling circuit.
Alarm output relay indicates that FACP input is triggered.
Green LED indicates FACP disconnect is triggered.
115VAC 60Hz. input.
Filtered and electronically regulated output(s).
Short circuit and thermal overload protection.
Built-in charger for sealed lead acid or gel type batteries.
Zero voltage drop upon transfer to battery backup.
Automatic switch over to stand-by battery when AC fails.
AC fail, low battery and battery presence supervision.
AC input and DC output LED indicators.
Includes cam lock and battery leads.
AL600ULACM
access power controllers with power supply/chargers