Specifications
3.12
Request the latest literature and guides from Anixter.
1.800.ANIXTER • anixter.com/literature
Power Supplies
Altronix
Power
D
Power Supplies/Chargers;Access Control/3290
Index1.Netw orking Systems //Video Products//Video Sec
urity Systems
ALTRONIX PR23155V2-160630.eps
These Altronix multi-output access control power sup
ply/chargers are specifically
designed for use with access control systems and accessories. These power supplies
convert a 115 V AC input into five individually regulated 12 V DC or 24 V DC power
limited outputs. Each output will route power to a variety of access control hardware
devices including mag locks, electric strikes, magnetic door holders, etc. These
outputs will operate in both Fail-Safe and Fail-Secure modes. Controlled trigger input
is achieved through normally open (N.O.) or normally closed (N.C.).
FEATURES
• UL Listed (UL 1481, UL 294) and C(UL) Listed, CSFM and MEA approved,
NFPA 72 compliant
• Class 2 Rated power limited outputs
• Input 115 V AC
• Five (5) individual power limited outputs
• Current limit is 2 amp @ 12 V DC or 24 V DC per output
• LEDs indicate condition of power outputs
• Power and input trigger LEDs
• AC fail, DC output, battery fail and battery presence supervision
• Fire alarm panel or access control system trigger inputs
• Power fail supervision relay
• Output relay energizes when unit is triggered
Power Supplies;General Purpose/3084
Index1.Netw orking Systems //Video Products//Video Sec
urity Systems
ALTRONIX PR23151V2-160618.eps
These units convert one (1) 12 to 24 V AC or DC input into eight (8) independently
controlled fused or PTC protected outputs. These power outputs can be converted to
dry Form C contacts (ACM8 and ACM8E only). Outputs are activated by an open
collector sink or normally open (N.O.) dry trigger input from an access control system,
card reader, keypad, push button, PIR, etc. The unit will route power to a variety of
access control hardware devices including mag locks, electric strikes, magnetic door
holders, etc. Outputs will operate in both Fail-Safe and/or Fail-Secure modes. Units
are designed to be powered by one common power source which will provide power
for both the board operation and locking devices, or two (2) totally independent
power sources, one (1) providing power for board operation and the other for lock/
accessory power. The FACP interface enables emergency egress, alarm monitoring or
may be used to trigger other auxiliary devices. The fire alarm disconnect feature is
individually selectable for any or all of the eight (8) outputs.
FEATURES
• 12 to 24 volt AC or DC operation (setting not required, .6 amp @ 12 volt,
.3 amp @ 24 volt current consumption with all relays energized)
• Power supply input options: a) One (1) common power input (board and lock
power) b) Two (2) isolated power inputs (one (1) for board power and one (1) for
lock/hardware power)
• Eight (8) access control inputs
• Eight (8) independently controllable outputs
• Eight (8) auxiliary power outputs (unswitched)
• Fire alarm disconnect (latching or non-latching) selectable by output
• Removable terminal blocks facilitate ease of installation
Power Supplies;General Purpose/3289
Index1.N etworking Systems //Video Produc ts//Video Sec urity Systems
ALTRONIX PR23158V2-160643.eps
These Altronix Power Supplies distribute and route p
ower to access control systems
and accessories. They will convert a 115 V AC 50/60 Hz input into eight (8)
independently controlled fuse or PTC-protected Class 2 power limited 12 V DC or 24 V
DC outputs. These outputs can also be configured as dry Form C contacts. Outputs
are activated by an open collector sink or normally open (N.O.) dry trigger input from
an access control system, card reader, keypad, push button, PIR, etc. The unit will
route power to a variety of access control hardware devices including: mag locks,
electric strikes, magnetic door holders, etc. Outputs will operate in both Fail-Safe
and/or Fail-Secure modes. The FACP Interface enables emergency egress, alarm
monitoring or may be used to trigger other auxiliary devices. The fire alarm
disconnect function can be configured for the following modes; a) Eight (8) outputs
affected. b) four (4) outputs affected and four (4) outputs unaffected (50/50 mode).
Five Output Power Supply/Charger with Fire Alarm Disconnect
Anixter No. Vendor No. Description
240604 AL300ULM 2.5 amp continuous @ 12 V DC or 24 V
DC (UL 294, UL 603, UL 1069, UL 1481)
243302 AL400ULM 12 V DC/24 V DC selectable, 4 amp, 12 V
DC, 3 amp, 24 V DC, five outputs
243301 AL600ULM 6 amp continuous @ 12/24 V DC
(UL 294, UL 1481)
258190 AL1012ULM 10 amp continuous @ 12 V DC (UL 294)
258191 AL1024ULM 10 amp continuous @ 24 V DC (UL 294,
UL 1481)
Access Power Controller
Anixter No. Vendor No. Description
231068 ACM8 8-zone access power controller, fused
274069 ACM8E 8-zone access power controller, fused,
with enclosure (UL 294)
243299 ACM8CB 8-zone access power supply with PTC
274070 ACM8CBE 8-zone access power controller, PTC, with
enclosure (UL 294)
Distributed Access Power Controllers with Power Supplies
S03Dat2.fm Page 12 Tuesday, December 11, 2012 10:00 PM