Installation Guide
- 2 - Trove / CDVI
Overview:
Trove1C1, Trove2CV2 and Trove3CV3 accommodate various combinations of CDVI boards with or without Altronix power supplies and
accessories for access control systems.
Specifications:
• 16 Gauge grey backplane and enclosure with ample knockouts for convenient access.
Installation Instructions for Trove1, Trove2, Trove3:
1. Remove backplane from enclosure prior to mounting (do not discard hardware).
2. Trove1C1 (Pg. 8):
Mark and predrill holes on the wall to line up with the top two keyholes in the enclosure. Install two upper fasteners and screws in
the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two upper screws; level and secure.
Mark the position of the lower two holes. Remove the enclosure. Drill the lower holes and install the two fasteners.
Place the enclosure’s upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws.
Trove2CV2 and Trove3CV3 (Pg. 10 and Pg. 12):
Mark and predrill holes on the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws in
the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the three upper screws; level and secure.
Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners.
Place the enclosure’s upper keyholes over the three upper screws. Install the three lower screws and make sure to tighten all screws.
3. Mount included UL Listed tamper switch(es) (Honeywell Model 112 or equivalent)
in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of
the enclosure approximately 2” from the right side (Fig. 1, pg. 2).
Connect tamper switch wiring to the Access Control Panel input or the appropriate
UL Listed reporting device. To activate alarm signal open the door of the enclosure.
4. Mount Altronix/CDVI modules to TC1, TCV2 or TCV3 backplane, refer to pages 3, 4, 5.
Edge of
Enclosure
to Access Control Panel
or U.L. Listed
Reporting Device
Enclosure
Honeywell
model # 112
Tamper Switch
or equivalent
(provided)
Fig. 1
Trove1C1
Trove1 enclosure with
TC1 Altronix/CDVI backplane
• Includes: tamper switch, cam lock,
and mounting hardware.
Enclosure Dimensions (H x W x D):
18” x 14.5” x 4.625”
(457mm x 368mm x 118mm).
TC1
Altronix/CDVI backplane only
• Includes mounting hardware.
Dimensions (H x W x D):
16.625” x 12.5” x 0.3125”
(422.3mm x 317.5mm x 7.9mm).
TC1 accommodates a combination
of the following:
Altronix Modules:
• One (1) AL400ULXB2, AL600ULXB,
AL1012ULXB, AL1024ULXB2,
eFlow4NB, eFlow6NB, eFlow102NB or
eFlow104NB.
• One (1) ACM4(CB), MOM5, PD4UL(CB),
PD8UL(CB), PDS8(CB), VR6.
CDVI Modules:
• Four (4) A22NB modules.
Trove2CV2
Trove2 enclosure with
TCV2 Altronix/CDVI backplane
• Includes: tamper switch, cam lock,
and mounting hardware.
Enclosure Dimensions (H x W x D):
27.25” x 21.75” x 6.5”
(692.15mm x 552.5mm x 165.1mm).
TCV2
Altronix/CDVI backplane only
• Includes mounting hardware.
Dimensions (H x W x D):
25.375” x 19.375” x 0.3125”
(644.5mm x 482.6mm x 7.9mm).
TCV2 accommodates a combination
of the following:
Altronix Modules:
• Two (2) AL400ULXB2, AL600ULXB,
AL1012ULXB, AL1024ULXB2,
eFlow4NB, eFlow6NB, eFlow102NB or
eFlow104NB.
• One (1) ACM8(CB), or two (2) MOM5,
PD4UL(CB), PD8UL(CB), PDS8(CB),
VR6.
CDVI Modules:
• Five (5) A22NB modules.
Trove3CV3
Trove3 enclosure with
TCV3 Altronix/CDVI backplane
• Includes: two (2) tamper switches, cam
lock, and mounting hardware.
Enclosure Dimensions (H x W x D):
36.12” x 30.125” x 7.06”
(917.5mm x 768.1mm x 179.3mm).
TCV3
Altronix/CDVI backplane only
• Includes mounting hardware.
Dimensions (H x W x D):
34” x 28” x 0.3125”
(863.6mm x 711.2mm x 7.9mm).
TCV3 accommodates a combination
of the following:
Altronix Modules:
• Up to four (4) AL400ULXB2,
AL600ULXB, AL1012ULXB,
AL1024ULXB2, eFlow4NB, eFlow6NB,
eFlow102NB or eFlow104NB.
• Up to four (4) ACM8(CB), MOM5,
PD4UL(CB), PD8UL(CB), PDS8(CB),
VR6.
CDVI Modules: