Installation Guide

Trove / CDVI - 3 -
Standoff
CDVI - A22NB
Access Controller
Backplane
Fig. 2b
TC1: Configuration of Altronix Power Supply
and/or Sub-Assembly Boards and CDVI Modules
1. Fasten standoffs (provided) to pems that match the hole pattern for Altronix Power Supply/Chargers or Altronix Sub-Assembly boards
(Fig. 2, pg. 3). Fasten metal standoffs in the correct locations to provide proper grounding, see below (Fig. 2, pg. 3).
2. Mount boards to standoffs utilizing 5/16” pan head screws (provided) (Fig. 2a, pg. 3).
3. Mount appropriate CDVI A22NB modules into the correct positions (Fig. 2, pg. 3) by postioning standoffs over appropriate holes on
the backplane and depress down on board to secure standoff to the backplane (Fig. 2, 2b, 2c, pg. 3).
Note: CDVI A22NB modules have one (1) RJ45 jack each. Please make sure that they are mounted correctly, as shown in Fig. 2 below.
4. Fasten TC1 backplane to Trove1 enclosure utilizing pan head screws (provided).
Fig. 2 - Trove1C1/TC1 Configurations
Plastic Standoff
pre-mounted into
CDVI Atrium modules
Insert into
TC1/TCV2/TCV3 backplane
Fig. 2c
CDVI - A22NB CDVI - A22NBCDVI - A22NB
CDVI - A22NB CDVI - A22NBCDVI - A22NB
Altronix
Power
Supply
Altronix
Sub-
Assembly
Metal
Standoff
Placement
RJ45 Jack RJ45 Jack RJ45 Jack
RJ45 JackRJ45 JackRJ45 Jack
Pem
Standoff
Altronix
Power Supply or
Sub-Assembly
Backplane
Pan Head
Screw
Fig. 2a