Trove2Z2/TZ2_Rev. 013118 Access & Power Integration Trove2Z2 - Trove2 enclosure with Altronix/ZKTeco backplane (TZ2) TZ2 - Altronix/ZKTeco backplane only Installation Guide All registered trademarks are property of their respective owners. More than just power.™ Trove2Z2/TZ2_Rev. 013118 Installing Company: ______________________ Service Rep.
Overview: Trove2Z2 accommodates various combinations of ZKTeco door controllers with or without Altronix power supplies and accessories for access control systems. Specifications: Trove2Z2 • Includes: tamper switch, cam lock, board mounting hardware. • 16 Gauge grey enclosure with ample knockouts for convenient access. Enclosure Dimensions (H x W x D): 27.25” x 21.75” x 6.5” (692.2mm x 552.5mm x 165.1mm). Accommodates up to four (4) 12VDC/7AH batteries. TZ2 • 16 Gauge.
Installation Instructions for Altronix Power Supplies and/or Sub-Assemblies to TZ2: 1. Fasten standoffs (included) to pems that match the hole pattern for Altronix Power Supply/Chargers or Altronix Sub-Assembly boards (Fig. 2, pg. 3). Fasten metal standoffs in the correct locations to provide proper grounding, see below (Fig. 2, pg. 3). 2. Mount boards to standoffs utilizing 5/16” pan head screws (included) (Fig. 2, 2a, pg. 3).
Installation Instructions for ZKTeco Modules to TZ2: 1. Fasten DIN Rail (provided by ZKTeco) to pem standoffs, utilizing 5/16” pan head screws (included) (Fig. 3, pg. 4). 2. Mount ZKTeco modules to DIN Rail (refer to below chart for model number, Fig. 3, pg. 4). 3. Fasten TZ2 backplane to Trove2 enclosure utilizing lock nuts (provided by Altronix). Pem Mounting Altronix Model C SMB/Pro Series inBio 460 D SMB/Pro Series inBio160/260 Fig.
Installation Instructions for ZKTeco Boards to TZ2: 1. Fasten standoffs (provided) to pems that match the hole pattern for ZKTeco boards (refer to below chart for model number, Fig. 4, pg. 5). 2. Mount ZKTeco boards to standoffs utilizing 5/16” pan head screws (included) (refer to below chart for model number, Fig. 4, pg. 5). 3. Fasten TZ2 backplane to Trove2 enclosure utilizing lock nuts (included). Pem Mounting Altronix Model E SMB/Pro Series C3 400 F SMB/Pro Series C3 100/200 Fig.
eFlow Power Supply/Chargers can be Controlled and Monitored while Reporting Power/Diagnostics from Anywhere over the Network... LINQ2 - Network Communication Module LINQ2 provides remote IP access to real-time data from eFlow power supply/chargers to help keep systems up and running at optimal levels.
TZ2 Dimensions (H x W x D): 25.375” x 19.375” x 0.325” (644.5mm x 482.6mm x 8.3mm) 19.375” (482.6mm) 7.5” (190.5mm) 24.95” (633.7mm) 7.5” (190.5mm) 0.156” ( 3.96mm) 12.62” (320.6mm) 16.245” (412.6mm) 25.375” (644.5mm) 8.5” (215.8mm) 12.62” (320.6mm) 1.0” (25.4mm) 0.45” (11.4mm) 1.0” (25.4mm) 7.5” (190.5mm) 7.5” (190.5mm) 9.2” (233.
Trove2Z2 Enclosure Dimensions (H x W x D): 27.25” x 21.75” x 6.5” (692.2mm x 552.5mm x 165.1mm) 21.50” (546.1mm) 2.00” (50.8mm) 5.25” (133.35mm) 3.50” (88.9mm) 3.50” (88.9mm) 5.25” (133.35mm) 0.685” (17.399mm) 1.25” (31.75mm) 0.5625” (14.29mm) 1.77” (44.96mm) 2.415” (61.34mm) Knockouts 1.125” (28.32mm) 0.885” (22.479mm) 6.25” (158.75mm) 0.85” (21.59mm) 6.25” (158.75mm) 1.25” (31.75mm) 19.80” (502.92mm) 1.5” (38.1mm) 2.00” (50.8mm) 6.75” (171.45mm) G 8.25” (209.54mm) 27.00” (685.8mm) 8.