Installation Guide

- 2 - Trove / Lenel
Overview:
Altronix Trove1M1, Trove2M2 and Trove3M3 accommodate various combinations of Lenel boards with or without Altronix power supplies and
sub-assemblies for access systems.
Specifications:
Trove1M1
Trove1 enclosure with TM1 Altronix/Lenel backplane.
16 Gauge grey enclosure with ample knockouts for convenient access.
Includes: tamper switch, cam lock, lock nuts and mounting hardware.
Enclosure Dimensions (H x W x D): 18” x 14.5” x 4.625” (457mm x 368mm x 118mm).
TM1
Altronix/Lenel backplane.
16 Gauge backplane.
Includes mounting hardware.
Dimensions (H x W x D): 16.625” x 12.5” x 0.3125” (422.3mm x 317.5mm x 7.9mm).
See TM1 Sub-Assembly Position Chart on Pg. 3 for the list of compatible sub-assemblies.
Trove2M2
Trove2 enclosure with TM2 Altronix/Lenel backplane.
16 Gauge grey enclosure with ample knockouts for convenient access.
Includes: tamper switch, cam lock, lock nuts and mounting hardware.
Enclosure Dimensions (H x W x D): 27.25” x 21.75” x 6.5” (692.2mm x 552.5mm x 165.1mm).
TM2
Altronix/Lenel backplane only.
16 Gauge backplane.
Includes: lock nuts and mounting hardware.
Dimensions (H x W x D): 25.375” x 19.375” x 0.3125” (644.5mm x 492.1mm x 7.9mm).
See TM2 Sub-Assembly Position Charts on Pgs. 5, 7, 8 for the list of compatible sub-assemblies.
TMV2 - Optional Door Backplane
Fits Altronix Trove2 enclosure.
Dimensions (H x W x D): 23.75” x 18.125” x 0.3125” (603.3mm x 460.4mm x 7.9mm).
See TMV2 Sub-Assembly Position Chart on Pg. 9 for the list of compatible sub-assemblies.
Trove3M3
Trove3 enclosure with TM3 Altronix/Lenel backplane.
16 Gauge grey enclosure with ample knockouts for convenient access.
Includes: two (2) tamper switches, cam lock, lock nuts and mounting hardware.
Enclosure Dimensions (H x W x D): 36.12” x 30.125” x 7.06” (917.5mm x 768.1mm x 179.3mm).
TM3
Altronix/Lenel backplane only.
16 Gauge backplane.
Includes: lock nuts and mounting hardware.
Dimensions (H x W x D): 34” x 28” x 0.3125” (863.6mm x 711.2mm x 7.9mm).
See TM3 Sub-Assembly Position Charts on Pgs. 10, 12 for the list of compatible sub-assemblies.
Agency Listings (When Using Altronix and Lenel Sub-Assemblies)*:
UL 294 - 6th edition. Trove1M and Trove2M Power Controllers: Line Security I, Destructive Attack I, Endurance IV, Stand-by Power II*.
*Stand-by Power Level I if no battery is supplied.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme á la norme NMB-003 du Canada.
*Trove3M3 and TM3 are not evaluated by UL.
Environmental:
Humidity and Temperature conditions as tested by UL (85%, +/-5% @ 30ºC +/-2ºC), ULC (93%, +/-2% @ 32ºC +/-2ºC).
Battery Backup:
Trove1 enclosure accommodates up to two (2) 12VDC/7AH batteries.
Trove2 enclosure accommodates up to two (2) 12VDC/12AH batteries.
Trove3 enclosure accommodates up to four (4) 12VDC/12AH batteries.
For more detailed information refer to Trove Installation Guide, Rev. 101817.
Hardware:
Snap On Standoff | Standoff (Metal or Nylon) | 5/16” Pan Head Screw | 7/8” Pan Head Screw | Lock Nut