Installation Guide
- 7 - Trove / Lenel
Installation Instructions for Lenel Access Controllers to TM2:
1. Fasten snap on standoffs onto metal pems configuration (A) (B) of backplane depending on the access controller (Fig. 4, pg. 7).
2. Position access controller module over corresponding standoffs and depress onto snap on standoffs (Fig. 4a, pg. 7).
3. Mount backplane to enclosure with hardware.
Access Controller Position Chart for the Following Models:
Lenel
Pem
Mounting
Current Draw Refer to
LNL-3300
A
12-24VDC 300mA max. LNL-3300 Quick Reference (QR50L-1001E — revision 2.023)
LNL-8000 12VDC 250mA max. LNL-8000 Quick Reference (QR50L-1000E — revision 1.020)
LNL-2220
B
12-24VDC 500mA max. LNL-2220 Quick Reference (QR50L-1002E - revision 2.022)
LNL-4420 12-24VDC 500mA max.
LNL-4420 Quick Reference
(QR50L-1024E-LNL-4420 - revision 1.001)
LNL-1100 12-24VDC 350mA max. (12VDC @ 300mA nom., 24VDC @ 220mA nom.)
LNL-1100 Series 2 Quick Reference
(QR50L-1010E - revision 1.019)
LNL-1200 12-24VDC 1100mA max. (12VDC @ 850mA nom., 24VDC @ 450mA nom.)
LNL-1200 Series 2 Quick Reference
(QR50L-1009E — revision 1.019)
LNL-1320 12-24VDC 550mA max. (12VDC @ 450mA nom., 24VDC @ 270mA nom.)
LNL-1320 Series 2 Quick Reference
(QR50L-1007E — revision 1.020)
Fig. 4
BA BA
BA BA
BA BA
Snap on or
Metal
Standoff
Sub-Assembly
Backplane
Pem
Fig. 4a