FIXED PANEL INSTALLATION
INSTALLATION MANUAL
1d
Front opening
Side opening
4836 / 6036 / 6042 / 6048 / 7236
1a
1b
1c
INTERIOR
SHOWER SIDE
Repeat on opposite side
Repeat on opposite side
INTERIOR
SHOWER SIDE
Use a measuring tape to mark the center of the
threshold.
Place the wall jambs against the wall so that
the holes are located towards the interior of the
shower. Center the opening of the wall jamb on
the line marked previously.
Insert one drop of silicone in each hole bored in
the wall before inserting there wall plug on both
side.
Screw the two wall jambs in the wall plugs
already installed in the wall by using screws 1
3/8’’ (3). Ensure verticality with the level.
1a.
1b.
1c.
1d.
THIS INSTALLATION PROCEDURE APPLIES FOR
ALL RETURN PANELS INSTALLATION REGARD-
LESS OF QUANTITY OR ADDITIONAL FIXTURE
SUCH AS TOWEL BAR.
Opening
FRONT SIDE
MODEL MIN MAX MIN MAX
4836 45 5/16” 46” 33 5/16” 34”
6036 57 5/16” 58” 33 5/16” 34”
6042 57 5/16” 58” 40 1/8” 40 13/16”
6048 57 5/16” 58” 46 1/8” 46 13/16”
7236 69 1/4” 70” 33 5/16” 34”
See the table