User's Manual

Chapter 3 - Operation and Administration Using the CLI Managing BSs
4Motion 493 System Manual
]
NOTE
An attempt to configure the cqi-ack-ranging parameter will be ignored. The value of this parameter
is set by internal logic.
Command
Syntax
npu(config-bs-66053-pwrctrl)# nilevels [cqi-ack-ranging <(-150 to
-22.5 StepSize 0.5)> ] [pusc <(-130 to -110 StepSize 0.5)> ]
[power-control-correction-factor <(-20 to 30 StepSize 0.1)>]
Privilege
Level
10
Syntax
Description
Parameter Description Presence Default
Value
Possible
Values
[cqi-ack-ranging
<(-150 to -22.5
StepSize 0.5)>
]>
Target Noise and
interference level for the
CQI, ACK and periodic
ranging regions, in dBm.
In the current release
the value is set by
internal logic. An attempt
to set a different value
will be ignored.
Optional -128 -150 to -22.5 in
steps of 0.5
[pusc <(-130 to
-110 StepSize
0.5)> ]
Target Noise and
interference level for the
PUSC zone, in dBm.
Optional -127 -130 to -110 in
steps of 0.5
[power-control-c
orrection-factor
<(-20 to 30
StepSize 0.1)>]
Correction (in dB) of
max allowed UL SINR
given DL SINR
measurement.
The higher the
correction factor is, the
higher is the allowed UL
Tx Power.
Optional 10 -20 to 30 in
steps of 0.1.
Command
Modes
bs power control configuration mode